Setting the number of motors from one to two depending on how many gate-
leaves the system has.
[Motor Type]
[FROG] / [AXO] / [FAST] / [FERNI] / [FROG PLUS]
[FROG]
Setting the type of operator for the swing gates on the system.
For AXO motors with cod. 001AX302304 and 001AX402306 set the slow-down
speed to the maximum value. The setting is in any case subject to an on-site
system-compliance inspection, pursuant to European Directive 2006/42/CE.
[Sleep Mode]
[Disabled] / [Enabled]
[Disabled]
For allowing the photocells to save energy in stand-by mode (with the RGP1
module connected).
[CRP Address]
[1]
……
[32]
[1]
With systems fitted with several operators and the CRP (Came Remote Protocol)
system connection, set an address between 1 and 32 for each control panel.
[CRP Baudrate ]
[1200] / [2400] / [4800] / [9600] / [19200] / [38400] /
[57600] / [115200]
[38400]
Setting the communication speed used in the CRP (Came Remote Protocol)
connection system.
[ENCODER]
&
Only viewable if the corresponding function is selected in [Config] in the [FUNCTIONS] menu
[Sensitivity]
[Enabled] / [Disabled]
[Enabled]
Obstruction detection sensitivity.
[Swing Sens.]
[-
◦◦◦◦◦◦◦◦
+]
[-
・◦◦◦◦◦◦◦
+]
Obstruction detection sensitivity during gate swing (both opening and closing).
&
You need to enable the
[Sensitivity]
in the
[ENCODER] menu
.
[Slodwn. Sens.]
[-
◦◦◦◦◦◦◦◦
+]
[-
・◦◦◦◦◦◦◦
+]
Obstruction detection sensitivity during slow-down (both opening and closing).
&
You need to enable the
[Enc. Slodwn.] function
in the
[ENCODER] menu
.
[Enc. Slwdwn.]
[ON] / [OFF]
[ON]
Enabling the opening and closing slow-down starting points.
[M1 Op. SloDwn.
%]
[1%]
……
[60%]
[10%]
Setting the starting slow-down of M1 before the opening limit-switch point,
calculated as a percentage (from 1% to 60% of the full leaf-swing).
&
This function only appears if the
[Enc. Slodwn.] function is enabled
in the
[ENCODER] menu
.
[M1 Slow. CH %] [1%]
……
[60%]
[10%]
Setting the starting slow-down of M1 before the closing limit-switch point,
calculated as a percentage (from 1% to 60% of the full leaf-swing).
&
This function only appears if the
[Enc. Slodwn.] function is enabled
in the
[ENCODER] menu
.
[M2 Appr. AP %] [1%]
……
[60%]
[10%]
Setting the starting slow-down of M2 before the opening limit-switch point,
calculated as a percentage (from 1% to 60% of the full leaf-swing).
&
This function only appears if the
[Enc. Slodwn.] function is enabled
in the
[ENCODER] menu
.
[M2 Slow. CH %] [1%]
……
[60%]
[10%]