Page
13
- Manual
FA00993-EN
- 12/2018 - © C
AME S.p.A. -
Tr
anslation of the original instructions
5"
max
Deleting all users
Set DIP-switch 4 to ON.
Keep pressed for about 10 seconds the PROG button on the control board. The programming LED will
perform a series of average length flashes (about 4 seconds) and quick flashes (about 2 seconds) until it it
switches off.
Reset DIP-switch 4 to OFF.
Deleting a single user
Set DIP-switch 4 to ON.
Keep pressed the PROG button on the control board. The programming LED flashes.
Within five seconds, press the button on the transmitter of the user you wish to delete. The LED will flash
quickly for one second to signal that the user has been deleted, and then it will switch off.
Reset DIP-switch 4 to OFF.