Safety devices
Photocells
Input for photocells or magnetic loop.
Reopening during closing. When the barrier is closing, opening the contact causes the movement to invert until
the barrier is fully open.
If the safety device is not used, short-circuit the input 2 - C1.
Photocells safety test
At each opening and closing command, the control board checks the efficacy of the safety devices.
Any anomalies will inhibit all commands.
Enable the function by setting DIP-switch 3 to ON.