GENERAL PRECAUTIONS FOR INSTALLERS

⚠ 

Important safety instructions.

⚠ 

Follow all of these instructions. Improper installation can cause serious 

bodily harm. 

Use this product only for its specifically intended use. Any other use is hazardous. 

• The manufacturer cannot be held liable for any damage caused by improper, 

unreasonable, and erroneous use. • This product is expressly designed to be 

assembled to partly-completed machinery or equipment so as to build machinery 

as regulated by the Machinery Directive 2006/42/EC. • The final installation must 

comply with the Machinery Directive 2006/42/CE and with the currently applicable 

European standards. • The manufacturer declines any liability for using non-original 

products; which would result in warranty loss • All procedures mentioned in this 

manual must be only be performed by skilled, qualified technicians and in full 

compliance with current regulations. • Laying of cables, installation and testing 

must follow state-of-the-art procedures as dictated by applicable standards and 

laws. • During all phases of the installation make sure you have cut off the mains 

power source. • Check that the temperature ranges given and those of the location 

match. • Before the installation, check that the guided part is in good mechanical 

condition, and that it opens and closes correctly. • Take care not to wet the operator 

with direct jets of water (sprinklers, water cleaners, etc.). • Make sure the anchoring 

spot is clear of any potential impacts, that the anchoring surfaces are solid, and 

that elements suitable  for the type of surface (for example screws and wall plugs) 

are used. • Make sure you have set up a suitable dual pole cut off device along the 

power supply that is compliant with the installation rules. It should completely cut 

off the power supply according to category III surcharge conditions. • Demarcate 

properly the entire site to prevent unauthorized personnel to enter; especially children 

and minors. • Use suitable protections to prevent any mechanical hazards due to 

persons loitering within the operating range of the operator. • The electric cables 

must pass through special pipes, ducts and cable glands in order to guarantee 

adequate protection against mechanical damage. • The electrical cables must not 

touch any parts that may overheat during use (such as the motor and transformer). 

• All fixed controls must be clearly visible after installation, in position that the 

guided part is directly visible, but far away from moving parts. In the case of a 

maintained action command, this must be installed at a minimum height of 1.5 m 

from the ground and must not be accessible to the public. • If not already present, 

apply a permanent tag, that describes how to use the manual release mechanism, 

close to the mechanism • Make sure that the operator has been properly adjusted 

and that the safety and protection devices, and the manual release, are working 

properly • Before turning over to the final user, check that the system complies 

Содержание ZL22N

Страница 1: ...CONTROL PANEL FOR 24 V GEARMOTORS ZL22N INSTALLATION MANUAL EN English FA00993 EN...

Страница 2: ...e operator with direct jets of water sprinklers water cleaners etc Make sure the anchoring spot is clear of any potential impacts that the anchoring surfaces are solid and that elements suitable for t...

Страница 3: ...sers Fit in plain sight the machine s ID plate when the installation is complete If the power supply cable is damaged it must be immediately replaced by the manufacturer or by an authorized technical...

Страница 4: ...use The ZL22N control panel was designed for controlling 24 V UNIPARK parking saver barriers Any installation and or use other than that specified in this manual is forbidden Technical data Type ZL22N...

Страница 5: ...ing 6 Button for programming 7 Terminal board for connecting the accessories 8 Terminal board for connecting the gearmotor 9 Terminal board for connecting control and safety devices 10 Terminal board...

Страница 6: ...x 1 5 mm 2 2G x 2 5 mm 2 TX Photocells 2 x 0 5 mm 2 RX photocells 4 x 0 5 mm 2 Accessories 2 x 0 5 mm 2 Command and control devices 2 x 0 5 mm 2 When operating at 230 V and outdoors use H05RN F type...

Страница 7: ...e to rotate Assemble the pressure hinges Fit the hinges into the box either on the right or left and fasten them using the supplied screws and washers Snap the cover onto the hinges Close it and secur...

Страница 8: ...e original instructions Input voltage 1 Power supply cable with double insulation 230 V AC 50 60 Hz 2 Accessories 24 V AC max 25 W power supply output 3 Control board power supply input Radio control...

Страница 9: ...onds from mode 1 to mode 2 the red LED flashes twice from mode 2 to mode 1 the red LED flashes once Each time the board is switched on if it is in mode 1 the red LED remains off if it is in mode 2 the...

Страница 10: ...RX TX RX TX Page 10 Manual FA00993 EN 12 2018 CAME S p A Translation of the original instructions if not used Safety devices Photocells Input for photocells or magnetic loop Reopening during closing W...

Страница 11: ...993 EN 12 2018 CAME S p A Translation of the original instructions The motor current consumption is proportional to the parking saver power Amperometric sensor sensitivity adjustment Sensitivity DIP s...

Страница 12: ...tor Before fitting the AF board you MUST CUT OFF THE MAIN POWER SUPPLY and remove any emergency batteries Adding a user If one or more LM22N boards are connected to the control panel it is not possibl...

Страница 13: ...gth flashes about 4 seconds and quick flashes about 2 seconds until it it switches off Reset DIP switch 4 to OFF Deleting a single user Set DIP switch 4 to ON Keep pressed the PROG button on the contr...

Страница 14: ...ld be disposed of as solid household waste and simply separated from other waste for recycling Whereas other components control boards batteries transmitters and so on may contain hazardous pollutants...

Страница 15: ...Page 15 Manual FA00993 EN 12 2018 CAME S p A Translation of the original instructions...

Страница 16: ...CAME S p A Via Martiri Della Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 16 Manual FA00993 PL 12 2018 CAME S p A Translation of the original instructions...

Отзывы: