GENERAL INSTALLATION INDICATIONS
⚠
Before working on the control panel, cut off the mains power supply and remove any batteries.
Cable types and minimum thicknesses
INSTALLING
Fastening the control panel
Fasten the control panel in a protected area using suitable screws and dowels.
Only use 6 x 70 mm cylinder-head screws.
Drill through the pre-drilled holes (18 and 20 mm) under the control panel's base.
⚠
Be careful not to damage the control board.
Enter the cable gland with the corrugated tubes for threading the electrical cables.
Connection
cable length
< 20 m
20 < 30 m
Control board power supply 230 V AC (1P+N)
2G x 1.5 mm
2
2G x 2.5 mm
2
Gearmotor 24 V AC
2G x 1.5 mm
2
2G x 2.5 mm
2
TX Photocells
2 x 0.5 mm
2
RX photocells
4 x 0.5 mm
2
Accessories
2 x 0.5 mm
2
Command and control devices
2 x 0.5 mm
2
When operating at 230 V and outdoors, use H05RN-F-type cables that are 60245 IEC 57 (IEC) compliant;
whereas indoors, use H05VV-F-type cables that are 60227 IEC 53 (IEC) compliant. For power supplies up to
48 V, you can use FROR 20-22 II-type cables that comply with EN 50267-2-1 (CEI).
Use RG58 cable up to 10 m long to connect the antenna.
If cable lengths differ from those specified in the table, establish the cable sections depending on the
actual power draw of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated
according to the actual power draw and distances. For connecting products that are not contemplated in this
manual, see the literature accompanying said products