CY input
Associate a function with the CY input.
F3
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during closure
C10 = Immediate closure during opening with obstacle standby during closure (NO contact)
C11 = Immediate closure during opening with obstacle standby during closure (NC contact)
C13 = Reopen while closing, with immediate closure once the obstruction has been removed, even if the boom is not in motion
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
CZ input
Associate a function with the CZ input.
F4
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during closure
C10 = Immediate closure during opening with obstacle standby during closure (NO contact)
C11 = Immediate closure during opening with obstacle standby during closure (NC contact)
C13 = Reopen while closing, with immediate closure once the obstruction has been removed, even if the boom is not in motion
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
F5
OFF (Default)
1 = CX
2 = CY
3 = CX+CY
4 = CZ
5 = CX+CZ
6 = CY+CZ
7 = CX+CY+CZ
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6
OFF (Default)
ON
Obstacle with motor stopped
With the function active and the operator stopped, an open or close command is not performed if the safety devices detect an obstacle.
F9
OFF (Default)
ON
Open warning light
Barrier status signal.
The device is connected to output 10-5.
F10
0 = Warning light on (default) - The light stays on when the boom is moving or open.
1 = Warning light flashing - The warning light flashes every half a second when the boom is opening and remains on when the
boom is open. The light flashes every second when the boom is closing, and remains off when the boom is closed.