ELECTRICAL CONNECTIONS

Passing the electrical cables

 Connect all wires and cables in compliance with the law.

The electrical cables must not touch any parts that may overheat during use (such as the motor and transformer).

Make sure that the moving mechanical parts are suitably far away from the wiring.

Power supply

Make sure the mains power supply is disconnected during all installation procedures.

 Before working on the control panel, disconnect the mains power supply and remove the batteries, if any.

Connecting to the electrical network

F

 Line fuse

L

 Phase wire

N

 Neutral wire

 Earth wire

F

230 V AC
50/60 Hz

Power supply output for accessories

The output normally delivers 24 V AC.

10 11 E1 TS 1

2

3 3P 4

5

7

2 CX CY CZ

E1 TS 1

2

3 3P

P 4

5

7

2 CXX CYY CZZ

Содержание GLT40AOS

Страница 1: ...Automatic road barriers GLT40AOS GLT40ROS GLT40ACS GLT40AX4 INSTALLATION MANUAL FA01748 EN EN English...

Страница 2: ...n these cases the tensioned springs no longer guarantee that the boom is balanced The boom may suddenly rotate when being released Manual release may cause the operator to move in an uncontrolled mann...

Страница 3: ...y 20 kg that needs hoisting for non manual handling use proper hoisting equipment in safe conditions When the operator is being fixed in place it may be unstable and overturn Be careful and do not lea...

Страница 4: ...uidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling Before dismantling and disposing of the produc...

Страница 5: ...MODELS GLT40AOS GLT40ROS GLT40ACS GLT40AX4 Power supply V 50 60 Hz 220 230 AC 120 AC 220 230 AC 220 230 AC Maximum current draw A 0 8 1 6 0 8 0 8 Motor power supply V 24 DC 24 DC 24 DC 24 DC Standby...

Страница 6: ...ate 4 Fastening flange 5 DIR DXR photocell holes 6 Lock for release 7 Cabinet 8 Inspection hatch 9 Inspection hatch lock 10 Control panel 11 Mechanical stop for the boom adjustment 12 Lever arm 13 Gea...

Страница 7: ...CRP connection 11 Terminal board associated with the RSE_2 connector for CRP connection IO 485 card or Modbus RTU interface 12 Terminal board for connecting the safety microswitch with cover open and...

Страница 8: ...pe H05RN F with designation 60245 IEC 57 For installation in an indoor environment use cables with properties at least equivalent to those of type H05VV F designation to 60227 IEC 53 If the cable leng...

Страница 9: ...astened in place Preliminary operations If the flooring does not allow the device to be fastened in a solid and stable way lay a cement slab Dig a hole for the foundation frame Set up the corrugated t...

Страница 10: ...d without notice Translation of the original instructions Fill the hole with soil around the concrete block Remove the nuts from the screws Thread the electrical cables into the tubes so that they pro...

Страница 11: ...Page 11 Manual FA01748 EN 04 2023 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions Fastening the barrier...

Страница 12: ...be changed at any time and without notice Translation of the original instructions Changing the boom opening direction Boom installation Fix the flange and the intermediate plate to the anchoring plat...

Страница 13: ...fixing the balance spring Passage width clearance m 2 00 2 25 2 25 2 75 2 75 3 25 3 25 3 50 3 50 3 75 3 75 4 00 Boom 1 1 1 2 2 Boom with anti collision profile and LED strips 1 1 2 2 3 3 Boom with sin...

Страница 14: ...12 x 120 Top spring attachment Bushing 13 8 Washer M8 Hex head screw M8 x 35 Bushing 19 M8 self locking nut M12 nut 1 Release the gearmotor 2 Position the boom vertically 3 Lock the gearmotor 4 5 6 As...

Страница 15: ...15 Manual FA01748 EN 04 2023 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions 8 Lubricate the spring when it is fully exte...

Страница 16: ...ions Balancing the boom 1 Release the gearmotor 2 Manually turn the spring to increase or reduce the traction The boom should stabilise at 45 3 Fasten the locknut Position the boom vertically 4 Lock t...

Страница 17: ...with mechanical limit switches Check that the boom is parallel to the road surface when it is in the closed position and at about 89 when it is in the open position Correct the boom s horizontal posi...

Страница 18: ...time and without notice Translation of the original instructions Correct the boom s vertical position Release the gearmotor Open the inspection hatch 1 Turn the mechanical stop until you reach the des...

Страница 19: ...tor and transformer Make sure that the moving mechanical parts are suitably far away from the wiring Power supply Make sure the mains power supply is disconnected during all installation procedures Be...

Страница 20: ...not used it must be deactivated during programming 2 Control device NO contact OPEN ONLY function When the HOLD TO RUN function is active the control device must be connected during OPENING 3 Control...

Страница 21: ...function F15 10 11 E1 TS 1 2 3 3P 4 5 7 2 CX CY CZ 3 1 R G Safety devices Connect the safety devices to the CX CY and or CZ inputs NC contacts During programming configure the type of action that must...

Страница 22: ...pairs can be connected See function F5 Safety devices test 10 11 E1 TS 1 2 3 3P 4 5 7 2 CX CY CZ 10 2 TX C NC TX 2 RX TX 10 11 E1 TS 1 2 3 3P 4 5 7 2 CX CY CZ 10 2 TX C NC TX 2 RX TX DXR DLX photocell...

Страница 23: ...e system the first manoeuvre is always to open the gate Wait for the manoeuvre to be completed Press the ESC button or STOP button immediately in the event of any faults malfunctions strange noises or...

Страница 24: ...closure C10 Immediate closure during opening with obstacle standby during closure NO contact C11 Immediate closure during opening with obstacle standby during closure NC contact C13 Reopen while clos...

Страница 25: ...ished for the time set under the function F25 Courtesy time Automatic closure Set the time before automatic closure is activated once the opening travel end point has been reached The function does no...

Страница 26: ...ations to a memory device memory roll or USB key The function is displayed only when a USB stick is inserted into the USB port or a memory roll card is inserted into the control board F50 OFF Default...

Страница 27: ...mber of vehicles which have to be authorised to pass through the gate The function can only be operated by control devices connected to the contact 2 3 The magnetic contact to which the loop that coun...

Страница 28: ...th a different type of radio coding saved previously will be deleted U4 1 All decoding default 2 Rolling code 3 TW key block Self Learning Rolling Save a new rolling code transmitter by activating acq...

Страница 29: ...ENTER to confirm deletion Forgotten password If you forget your password follow the procedure below Disconnect the control board from the power supply Press and hold the and buttons then reconnect th...

Страница 30: ...Page 30 Manual FA01748 EN 04 2023 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions FINAL OPERATIONS...

Страница 31: ...essories must be connected to the control board which will be set as the MASTER RSE A B GND S1 GND A B GND UTP CAT 5 max 1000 m RSE A B GND S1 GND A B GND Programming All programming operations descri...

Страница 32: ...or Connect up the electrics for the devices and accessories For information on connecting the electrics for the devices and accessories please see the ELECTRICAL CONNECTIONS section The control and sa...

Страница 33: ...23 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions 2 ONLY OPEN command 2 3 on barrier B 3 OPEN CLOSE command 2 7 on barrie...

Страница 34: ...oosing products and accessories please see our product catalogue If the barrier with an articulated joint is used check that the moving parts of the joint are in good condition Replace them if necessa...

Страница 35: ...n release hatch error E9 Obstacle detected during closing E10 Obstacle detected during opening E11 The maximum number of obstacles detected consecutively has been exceeded E12 No line voltage E14 Seri...

Страница 36: ...s of this manual may be changed at any time and without notice Translation of the original instructions AFFIX THE PRODUCT LABEL FROM THE BOX HERE CAME S p A Via Martiri della Libert 15 31030 Dosson di...

Отзывы: