Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
F34
10% to 100% (Default 100%)
10% = minimum thrust and high obstruction sensitivity
100 % =maximum thrust and low obstruction sensitivity
RSE
Configure the connector connections on RSE1 and RSE2.
If an RSE card – configured for paired connections – is plugged into the RSE_1 connector, use the RSE_2 connector for remote connection (CRP). In this case, a
CAME KEY cannot be connected.
F49
rE1
1 = Paired
3 = CRP/CAME KEY (Default)
4 = Alternate
rE2
3 = CRP/CAME KEY (Default)
5 = I/O - RS485
6 = ModBus
Save data
Save user data, timings and configurations to a memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or a memory roll card is inserted into the control board.
F50
OFF (Default)
ON (Run operation)
Read data
Load user data, timings and configurations from a memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or a memory roll card is inserted into the control board.
Upload user data, timings and configurations from the memory device (memory roll or USB key).
F51
OFF (Default)
ON (Run operation)
Transferring MASTER-SLAVE parameters
Share parameters programmed on the Master barrier with the Slave barrier.
This only appears if the F49 function is set to [Paired] or [Alternate].
F52
OFF (Default)
ON
Opening direction
Set the boom-opening direction.
F54
0 = To the left (default)
1 = To the right
CRP address
Assign a unique identification code (CRP address) to the control board.
F56
1 to 254