PROGRAMMING
Programming button functions
1
ESC button
The ESC button is used to perform the operations described below.
Exit the menu
Delete the changes
Go back to the previous screen
2
< > buttons
The <> buttons are used to perform the operations described below.
Navigate the menu
Increase or decrease values
3
ENTER button
The ENTER button is used to perform the operations described below.
Access menus
Confirm choice
During movement, outside the menu, the ESC key stops the barrier and the <> keys open and close the barrier.
Getting started
Once the electrical connections have been made, proceed with commissioning. Only skilled and qualified staff may perform this operation.
Check the warning and safety devices are working properly.
Make sure that there are no obstacles in the way.
Power up and proceed with the operations indicated below.
A1
Boom length
F54 Opening direction
A2
Motor test
F1
Total stop
A3
Travel calibration
After powering up the system, the first manoeuvre is always to open the gate Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the system.
If “A3” scrolls across the display, this means that the electronic board has not yet been calibrated.
At the end of commissioning, check the correct operation of the device using the buttons near the display. Check that the accessories also work correctly.
Functions menu
Total stop
This stops the boom and excludes automatic closing. Use a control device to resume movement.
F1
OFF (Default)
ON
CX input
Associate a function with the CX input.
F2
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during closure
C10 = Immediate closure during opening with obstacle standby during closure (NO contact)
C11 = Immediate closure during opening with obstacle standby during closure (NC contact)
C13 = Reopen while closing, with immediate closure once the obstruction has been removed, even if the boom is not in motion
r7 = Reopen while closing (sensitive edges with 8K2 resistor)