Configure maintenance
Set the number of manoeuvres the operator can perform before a maintenance warning signal is generated.
The warning is displayed as an [SEr] message and signalled by 3 + 3 flashes every hour on the device connected to the 10-5 output.
F58
OFF (Default)
1 to 999 (1 = 1000 manoeuvres)
Pre-flashing
Choose the type of manoeuvre that activates the flashing beacon in advance.
Set how much earlier the flashing beacon is activated under the function [Pre-flashing time].
F61
0 = when opening and closing (Default)
1 = only when closing
2 = only when opening
RSE speed
Set the communication speed of the remote connection system on the RSE_1 and RSE_2 ports.
F63
rE1
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
rE2
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
Opening counter
With the function active, you can send a series of opening commands corresponding to the number of vehicles which have to be authorised to pass through the gate. The
function can only be operated by control devices connected to the contact 2-3. The magnetic contact, to which the loop that counts vehicles in transit is connected, is
connected to an input. This input must be programmed to operate in C5/C9/C10 mode. At the end of the count the passage is closed.
F75
OFF (Default)
ON
Emergency battery operation
Emergency function in the event of a power outage. Batteries required.
F93
OFF (Default)
1 = Immediate opening
In the event of a power outage, the operator runs an opening command within 1 minute and all other commands are blocked until
power is restored.
New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must be
inserted into the connectors.
U1
1 = Step-by-step
2 = Sequential
3 = Open
4 = Partial opening
When the barrier is in [Paired] mode, the [Partial Opening] command opens the Master barrier.
Choose the function to be assigned to the user.
Press ENTER to confirm.
The free position in the memory is shown intermittently for a maximum of 10 seconds. During this phase, send the code from the
control device.
Repeat the procedure to add other users.