P
age
19
- Manual
FA01610-EN
- 08/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Maximum capacity of contacts
Device
Output
Power supply (V)
Power (W)
Accessories
10 - 11
24 DC
40
Additional light
10 - E1
24 DC
20
Flashing beacon
10 - E1
24 DC
20
Operator status warning light
10 - 5
24 DC
3
RGB LED strip
-
-
13,5
The sum of the power draw for the connected accessories must not exceed 40 W.
Command and control devices
1
Antenna with RG58 cable
2
Card reader
3
Transponder selector switch
4
Keypad selector
5
STOP button (NC contact)
This stops the boom and excludes automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
6
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
7
Control device (NO contact)
OPEN ONLY function
The contact must only be used for operators working in paired mode.
8
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
9
Control device (NO contact)
OPEN-CLOSE function
2
24
10
S1GND
A B
11 E1 E6 TS 1
2
3 3P 4
5
7
2 CX CY CZ
FA FC
STB
TAMPER
+
-
3
2
1
4
6
7
8
9
5