background image

IP7

ELECTRICAL

CABINET

C;;"'B

"

"

,-

"

.

"

.

"

,.

B

"':n.

8

B

u'"

8

~&

JJ~~

t~J##l

OPENKEY

TERMINAL

BOARD

FOR CONNECTION

OF

MOTOR-ENCODER-

BATIERY-POWER

SUPPLY

24V

SEAT FOR EMERGENCY

OPERATION

CARD

MA7032

DIP-SWITCHES

ADJUSTMENT

TRIMMERS

CONNECTION

FORFUNCTION

SWITCH

MA7041

CONNECTION

FOR"COMPASS"

OPERATING

SYSTEM

SEAl FOR PHOTOCEll CARD

MF9011-9111

'1 "Hl~

'UnCH)

7'

~ ~

61

","",0' ,

IlUUO\A

/IAA10011

CONNECTION

FORELECTRIC

LOCK

MA7012

B "
B "

B,
B ,

B "

EO •

B

M

B "

B "

B ,

TERMINAl

BOARD

FOR CONNECTION

OF ACCESSORIES

<D

POWER SUPPLY CONNECTION TERMINAL BOARD

24V

Reduction gear power supply (supplied standard)

...L

Earth connection

230V

Power supply (50/60 Hz)

Line fuse 2A

(see page 22)

TERMINAL BOARD FOR CONNECTION OF ACCESSORIES

@

10'

M

@

11.

10 - 11

24V a.c.ld.c. power to accessories

@

1

1

• 2

Pushbutton Stop, normally close contact (N.C.)

S

2

MAlOl:

2

- C1 Photocells, re-opening during closing (N.C.)

@

Cl

2

- Ri

Normally open contact (N.O.) for central sensor (used only

e

Ri

(![[

when interface system is installed)

S

M

2

- R1 Normally open contact (N.O.) external sensor (ean be excluded)

S

R2

2

- R2 Normally open contact (N.O.) internal sensor

@

Rl

(~

2

• M

Normally open contact (N.O.), for "step-by-step"

operation

@

2

(manual bullon)

. '.l..-.'

- Contact

1-2 and 2-C1 are normally closed (N.C.) and bridged together at the factory. To use these functions, replace

the bridge connections with the relative devices.

- The 2-C1 contact

is used when a security system is desired (for example, photoelectric

cells or other control

devices), which is noteapable

of being housed in the special clip-in seal Note if the MA9011/9111

photoelectric cell

card is not enabled

or if it is enabled and you wish to disable it, set dip switch 3to ON (4-way module).

- The 2-M contact

is normally open (N.O.), and has a double function:

1) During normal functioning it is enabled for opening, even if the MA7041 function selector is set on "doors closed".

This function ean be used for preferential passage, (e.g., evening closure, opening command on key or magnetic

switches).
2) By selling dip switch 5to ON (10-way module), the "stepper" opening function is enabled (by pressing the bullon

the door opens: pressing it again closes the door). Attention,

by using this function contacts 2-Rl and 2-R2 are

excluded.

Содержание Corsa Series

Страница 1: ...TION SYSTEM FOR SLIDING DOORS Ooeumorrtal lono e nIao M70 fCW 3 1 07f2000 eCAME CAJI Cf UI AUTOIllA j119PM70 AUTOMATION SYSTEM FOR SLIDING DOORS WITH MICROPROCESSOR CONTROL for door wings weighting I...

Страница 2: ..._ The trolleys can be used to adjust the alignment of the door wings as follows vertical adjustment RV with bolts and nuts A and B transverse adjustment RT with bolts and nuts C horizontal adjustment...

Страница 3: ...RSE ADJUSTMENT R The vertical plane of the rollers on the trolleys must be parallel with the beam If the trolleys are out of alignment i e if the door wing does not slide easily proceed as follows Loo...

Страница 4: ...vents the optional profile housing from oscillating and bending longitudinally One bracket can be installed when the beam is mounted at a height of up to 2 80 m while both brackets should be installed...

Страница 5: ...1 CHECKING FOR PROPER ASSEMBLY After the beam has been installed and all mechanical adjustments have been made made sure that _ no scraps of materials left by manufacturing processes remain on the gu...

Страница 6: ...l sensor ean be excluded S R2 2 R2 Normally open contact N O internal sensor Rl 2 M Normally open contact N O for step by step operation 2 manual bullon l Contact 1 2 and 2 C1 are normally closed N C...

Страница 7: ...mains power has been disconnected and the red power terminal has been removed from the emergency battery if installed ADJUSTMENT TRIMMERS II 0 111 MF9011 MF9111 11 II I 4 API ARZ lOA V RA LCH ADJUSTME...

Страница 8: ...ION FUNCTIONS 1 ON Activation of spring loaded anti panic device set dip switch 4 to ON constant push while closing 1D dip function selector see pag 19 2 Not used keep the dip in position OFF 3 ON Exc...

Страница 9: ...stem to re arm the electric lock if installed I If the automation system stops during the closing cycle the motor polarity may be incorrect If this occurs proceed as follows Disconnect the mains power...

Страница 10: ...Mf9011 MF9111 illI1 llfl L_ _ __ __ Anti panic device with constant battery control Note in case the MA7041 selector is not connected and you wish to activate the anti panic function bond contacts 1 3...

Страница 11: ...n command is given This is the default selling Locking with doors closed and open The unit locks both when open and closed when positioned correctly and is released electrically by each open and close...

Страница 12: ...Mechanical interference is occurring between moving door wings and non movin l parts for example door wings pavement non moving door wings mOVing door wings moving door wings pavement mounted guides w...

Отзывы: