CV-550 SPK V3 REFERENCE MANUAL
INSTALLATION INSTRUCTIONS
Page 15 of 33
4.1.4 Delete admin card
02, 0000#, delete all 21 admin cards.
02, 0#, delete 3 Set-cards.
02, 1#, delete 3 Add-cards.
02, 2#, delete 3 Delete-cards.
02, 3#, delete 3 Super-open-cards.
02, 4#, delete 3 Anti-duress-cards.
02, 5#, delete 3 Authorization-cards.
02, 6#, delete 3 Normal-open-cards.
4.1.5 Set Keypad Mode
03, 0#, Set to Reader mode.
03, 1#, Set to Single-door mode.
03, 3#, Set to Interlock mode.
03, 9#, Set to Demo mode.
Note: Factory default mode are Single-door mode, menu effect will be different in different mode.
The valid menus for Reader mode are:00-04,09,40-42,50-57,60-64, among them, menu 01 and 02 can only add and delete
admin password cards.
The valid menus for Single-door and interlock mode are: 00-04,09,10-12,20-22,30-36,40-45,50-57.
The valid menus for Demo mode are: 03,09,32,34,51-53,55.
4.1.6 Limits types of reading card
04, 0#, cannot read any card.
04, 1#, can read EM card only.
04, 2#, can read HID card only.
04, 4#, can read EM+HID card.
04, 7#, can read EM+HID+IC card.
Note: To read IC cards at 13.56MHz, a different model of keypad must be used.
4.1.7 Restore to default settings
09, 0000#
Note: After Restore to default settings, Admin Password is unchanged, Keypad mode is unchanged, admin cards and user
card information are not deleted, and the specific default values are shown in the appendix.