CV-550 SPK V3 REFERENCE MANUAL
INSTALLATION INSTRUCTIONS
Page 29 of 33
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #
Menu
Parameter or operation step
Function
Default value
30
0#
Open door way by card
2
1#
Open door way by card and PIN
2#
Open door way by card or PIN
31
1#
Set one card to open door
1
(1-10)#
Set 2-10 cards together to open door
32
0#
Set lock to Delay mode
0
1#
Set lock to Switch mode
2#
Set the lock to Normal-open mode
33
0#
Disable users to use.
1
1#
Enable users to use.
34
0#
Set Open-time to 50mS
2
(1-999)#
Set Open-time from 1 to 999S
35
(0-99)#
After opening the door, delay 0-99 seconds to
start the tone
10
36
(0-99)#
Set the closing prompt tone for 0-99 seconds.
10
40
0,#
Set the alarm time to 0, means no alarm
0
(1-99)#
Set the alarm time to 1-99 minutes
41
0#
Disable anti-dismantle alarm function.
0
1#
Enable anti-dismantle alarm function.
42
0#
Alarm lead output alarm signal voltage
0
1#
Alarm lead output doorbell signal voltage
43
0#
Normal operate mode
0
1#
Enable lock out alarm function
2#
Enable lock out locked function
44
(1-10)#
Set lock out wrong attempts 1-10
10
45
(1-99)#
Set lock out locked time 1-99 minutes
10
50
0#
Indicator light is always off
1
1#
Red indicator light is always on
2#
Green indicator light is always on (reader
mode)
51
1,1,…,#
Decrease the brightness of the normally
bright red indicator
18
2,2,…,#
Increase the brightness of the normally bright
red indicator
52
0#
Key backlit is always off
1
1#
Key backlit is always on
(2-99)#
After delay 2-99 seconds, Key backlit turn to
micro light
53
1,1,…,#
Decrease the brightness of the backlit
14
2,2,…,#
Increase the brightness of the backlit
54
0#
Disable the buzzer
1