![cam SHP Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/cam/shp-series/shp-series_operating-manual_3583528008.webp)
8/36
2.2.
Operating pressure and oil flow rate
Model
Operating pressure
Oil flow rate
Hydraulic
functions
Minimum Recommended Maximum Minimum Recommended Maximum
bar
bar
bar
l/min
l/min
l/min
SHP225
130
160
220
4
10
15
1
SHP335
130
160
220
6
12
18
1
A flow rate less than recommended will result in a lower rotating speed.
A flow rate greater than the maximum can result in excessive heating, reduced system
performance and reduced hydraulic system life.
2.3.
Main components of the product
3
3
2
1
4
5
6
N° Component
1
Cylinder connection
2
Cylinder
3
Lifting hook
4
Sliding pads
5
Frame
6
Locking tab
4
2
Содержание SHP Series
Страница 28: ...28 36 10 ANNEXES 10 1 CE certificate...
Страница 29: ...29 36...
Страница 30: ...30 36 10 2 Hydraulic diagram If you request a detailed hydraulic diagram please contact the manufacturer...
Страница 33: ...33 36 NOTES...
Страница 34: ...34 36 NOTES...
Страница 35: ...35 36 NOTES...