2013 Portable Spa
LTR20131000, Rev. E
Pr
eparing f
or
Your Ne
w P
or
tab
le Spa
www.calspas.com
8
OFF Position (Down)
ON Position (Up)
Test Mode OFF
A1
Test mode (normally OFF)
Standard / Economy /
Sleep Mode changes
allowed
A2
Standard Mode only
Use Digital Duplex or
Light Duplex plane
A3
Use Mini Panel
Pump 2 enabled
A4
Pump 2 disabled
Single voltage heating
(240VAC only)
A5
Dual voltage heating enabled
Safety Suction (must be
OFF)
A6
See table at right
A7
See table at right
Temperature displayed in
Fahrenheit
A8
Temperature displayed in
Celsius
No circ pump; Pump 1 is
two-speed
A9
Circ pump acts like Pump
1 low speed (filter cycle,
polling); Pump 1 is one-speed
See page 16 for description of
circulation pump operation.
See table at right
A10
See table at right
Note: Arrow indicates factory default setting.
Number of high speed pumps
that can be run before heater
is disabled (A5 OFF)
OR
before heater runs at 120VAC
(A5 ON)
No . of
Pumps
A7
A10
0
OFF
OFF
1
ON
OFF
2
OFF
ON
3
ON
ON
High Power Configuration
DIP Switch Definitions for 5100DV
Testing the GFCI Breaker
Test the GFCI breaker prior to first use and periodically when the spa is powered. To test the GFCI breaker
follow these instructions (spa should be operating):
Press the TEST button on the GFCI. The GFCI will trip and the spa will shut off.
1.
Reset the GFCI breaker by switching the breaker to the full OFF position, wait a moment, then turn the
2.
breaker back on. The spa should have power again.