28 APOLLO
Digital Broadcast Production Console
Control Surface
Any standard specification modern
PC running Windows 7 or Windows XP
Professional can be used as a backup
or replacement to connect to the
console and run the various Calrec
applications.
Connection by the PC's USB port, via the
supplied USB-Ethernet adaptor into a
spare POE switch P1 – P6 port ensures
the PC's network port is not damaged
by POE power. Note, not all available
USB-Ethernet adaptors have protection
against POE power, please refer to the
manufacturers specification if not using
ones supplied by Calrec.
Starting the Calrec Main Application on a
second PC will disable it on the first PC.
If using a laptop, or a different monitor
screen to the one supplied, a minimum
screen resolution of 1280 x 1024 is
required to display the Calrec software
correctly. Currently, such pixel height is
not widely supported by budget range
laptops. Using an alternative higher
resolution monitor such as 1920 x 1080
will display the Calrec software correctly
but the content will not scale up higher
than the 1280x1024 monitor size it was
designed for.
Calrec can supply pre-configured laptops
and replacement PC's ready to work
out of the box. The setup instructions
on this page can be used to configure
a non-Calrec supplied PC. Minimum
requirements for the PC are listed below.
FIGURE 2 - APOLLO BACKUP PC SETUP FOR WINDOWS
1. Download the latest version of Java Runtime Environment from
www.java.com
and
install it on the Backup PC.
2. Download the latest version of .net Framework from
www.microsoft.com/net
and
install it on the Backup PC.
3. Copy folder
C:\Calrec
from the Console PC onto the
C:
drive of the Backup PC.
4. Copy the folder
Drivers\WINXP\32 BIT
from the DUB E-100 Ethernet to USB
adaptor installation CD onto the
C:
drive of the Backup PC
5. Plug the USB connection of the DUB E-100 USB network adapter into the Backup
PC. Windows will automatically detect and start to install it. When prompted, select
Install from a specific location
and browse to the location the drivers were copied
to in the previous step. Follow the on-screen prompts to complete the installation
6. Once the DUB E-100 has been successfully installed, go to
Start>Control Panel>Network Connections
, right click on the connection
which uses the DUB E-100 and choose Rename. Rename the connection to
CalrecDeskConnection
(case sensitive) and click
OK
.
7. Right click on
CalrecDeskConnection
and select
Properties
, this will open the
Network Properties
window. Scroll down the list to find
Internet Protocol (TCP/
IP)
and double click on it. Select
Use the following IP address
. In the IP address
field enter
xxx.yyy.135.0
(where xxx.yyy match the first two bytes of the console IP
address. If uncertain, open the Calrec program updater application which will list all
the IP's in the system. They all have the same first two bytes). In the
Subnet Mask
field enter
255.255.0.0
, leave all other fields blank. Click on
OK
. You will be returned
to the Network Properties window
8. Select the
Advanced
tab and click on the
Windows Firewall Settings
button. Turn
the firewall off and click
OK
to confirm, then
OK
again to exit Network Properties.
9. Navigate to
C:\Calrec\WindowsService
on the Backup PC and double click on
install.bat.
10. Go to
Start>Control Panel>Administrative Tools>Services
. Right click on
CalrecService
and click
Start
.
11. Go to
Start>Control Panel>System
and open the Computer Name tab and make
a note of the full computer name. Go to
Start>Run
and type
cmd
then press
<enter>
. This will open a DOS command prompt. At the prompt type
c:
and press
<enter>
, then type
Calrec\Utils\setcacls
then press
<enter>
. When prompted
enter the full computer name and press
<enter>
.
12. Connect the DUB E-100 to the console using a spare panel port (P1-P6) on one of
the POE switches.
13. Navigate to
C:\Calrec\ConsolePC
on the Backup PC and double click on
run.bat
.
This will open the Main Application. Note that the Main Application and Program
Updater should not be running on the Console PC whilst the Backup PC is in use.
BACKUP PC
FIGURE 1 - MINIMUM PC SPEC
CPU
HDD
RAM
OS
Ports
1.6 GHz Dual Core
160 GB
1GB
Windows XP Pro
1 x USB or 1 x POE protected Ethernet port
Содержание Apollo
Страница 5: ...calrec com Putting Sound in the Picture APOLLO INFORMATION...
Страница 9: ...calrec com Putting Sound in the Picture APOLLO CONTROL SURFACE...
Страница 29: ...calrec com Putting Sound in the Picture APOLLO PROCESSING CORE...
Страница 35: ...calrec com Putting Sound in the Picture APOLLO CONNECTION INFORMATION...
Страница 59: ...calrec com Putting Sound in the Picture APOLLO EXTERNAL CONTROL...
Страница 72: ...72 APOLLO Digital Broadcast Production Console 72 APOLLO Digital Broadcast Production Console...
Страница 73: ...calrec com Putting Sound in the Picture APOLLO SETUP AND CONFIGURATION...
Страница 93: ...calrec com Putting Sound in the Picture APOLLO PANEL OPTIONS...
Страница 108: ...108 APOLLO Digital Broadcast Production Console 108 APOLLO Digital Broadcast Production Console...
Страница 115: ...calrec com Putting Sound in the Picture APOLLO SPECIFICATIONS...