117
POWER / ENVIRONMENTAL SPECIFICATION
CONTROL SURFACE
AC Power
The operating AC voltage is 100-240V +/-10%, 50-60Hz.
Two IEC AC power inlets on the rear of the control surface are internally distributed to twin
PSU POE switches located within the surface chassis which in turn power the main surface
components. Feeding either of these IEC connectors with mains power is sufficient for console
operation, however it is recommended that both are fed, and where possible from separate
sources to provide full redundancy in the event of an internal PSU or external power source
failure.
The inrush current is actively limited to 13A peak at 230 VAC (6.5A at 115VAC) per internal PSU
(Total number of internal PSU's is dependent on the number of POE switches fitted, typically
between 2 and 5 depending on the size of the control surface. Each switch contains two PSU's,
separately fed from the two IEC inputs). Limiting the inrush current reduces the chances of a
nuisance trip or blown fuse from brown-out conditions or black-out recovery. The peak operating
current is when all fader motors are active simultaneously, max 5W per fader for less than
120mS.
The internal PSU's are high efficiency and employ active PFC (Power Factor Correction).
The power factor is > 0.9 under all operating conditions.
A third IEC AC power inlet powers third party manufactured hardware in the control surface, such
as RTW / DK meters and the PC monitor screen).
DC Power
Internal AC-DC power supplies output 56V DC via POE (power over Ethernet) to the main
control surface components. DC power and data is shared over a common RJ45 connection.
All components can safely be 'hot-plugged', are self initialising and sync with the system on
receiving power. Each module locally performs isolated DC-DC conversion, operating over a
wide input range of 36-75V to provide a high level of immunity against surges, transients and
dips in supply.
Heat Output & Efficiency
The heat output from the console is typically 0.9 x total RMS VA.
PSU efficiency is typically > 85% under all operating conditions, depending on the control
surface size.
Cooling
The control surface is cooled by natural convection. Air intakes are located on the underside of
the chassis, outlet vents are located across the top of the rear. At least 50mm (2') clearance
should be maintained around the intakes and outlets to ensure airflow is unimpeded.
Operating Ambient Air
Temperature
Short term: 5ºC - 35ºC.
Long term: 15ºC - 30ºC.
Relative Humidity
5% - 80% Non-condensing.
Содержание Apollo
Страница 5: ...calrec com Putting Sound in the Picture APOLLO INFORMATION...
Страница 9: ...calrec com Putting Sound in the Picture APOLLO CONTROL SURFACE...
Страница 29: ...calrec com Putting Sound in the Picture APOLLO PROCESSING CORE...
Страница 35: ...calrec com Putting Sound in the Picture APOLLO CONNECTION INFORMATION...
Страница 59: ...calrec com Putting Sound in the Picture APOLLO EXTERNAL CONTROL...
Страница 72: ...72 APOLLO Digital Broadcast Production Console 72 APOLLO Digital Broadcast Production Console...
Страница 73: ...calrec com Putting Sound in the Picture APOLLO SETUP AND CONFIGURATION...
Страница 93: ...calrec com Putting Sound in the Picture APOLLO PANEL OPTIONS...
Страница 108: ...108 APOLLO Digital Broadcast Production Console 108 APOLLO Digital Broadcast Production Console...
Страница 115: ...calrec com Putting Sound in the Picture APOLLO SPECIFICATIONS...