RePlTran
Use the following procedure to replace a damaged or failed pluggable transceiver module.
!
DANGER!!CLASS!1!LASER!PRODUCT.!INVISIBLE!LASER!RADIATION!
MAY!BE!PRESENT.
!!Fiber!optic!radiation!can!cause!severe!eye!damage!or!
blindness.!Do!not!look!into!the!open!end!of!an!optical!fiber.!
To!replace!a!pluggable!transceiver!module!
1.!
Disconnect the fiber(s) from the module to replace, if present.
2.!
Remove the pluggable module from the E7-20 line card as follows:
a.
!
Unlock the latch on the module, if so equipped (latch styles vary).
b.
!
Gently pull the latch to unseat the module.
c.
!
Carefully slide the module out of the socket and set it aside.
3.!
Insert a replacement module into the vacant socket and re-connect fibers. See
Connecting the E7-20 Line Interfaces for detailed instructions.