A. On your circuit board find the Dip Switch setup (Page 15, #3), turn the OFF/ON switch to the ON
position.
B. Unscrew the back of the remote control to gain access to the control board. You should see
1-8 dip switches. Each switch has 3 positions: up, middle, bottom. Flip these 1-8 switches to
any random position you'd like, see Figure A.
C. On the gate opener control board, look for the same 1-8 dip switches (Page 15, #3), and set the
same combination as you did on the remote.
D. Finished.
By default, the remote controls are already connected to the gate operator. You do not need to do
any of the following steps unless you are adding more remote controls.
This gate operator can add up to 50 different remote controls. To add more than 50 remote controls,
add a receiver, which can add up to 100 additional remote controls. Calimet remote controls use 418
MHz frequency with a 300' max distance
There are two ways to connect your remote control: Learn & Dip Switch.
Learn
Connect using Learn On your gate operator circuit board, look for the study key (Page 15,
#4). Press and hold the button on the remote control. Press and hold the study key until
the flashing light turns solid, about 2 seconds. Done, the remote is now connected to the
gate opener.
Removing all existing remote controls Press the STUDY key on the gate operator circuit board and
hold for 8 seconds. Done. All remote controls are now removed.
Dip Switch
Only the CM9-509 red remote controls can be installed using the dip switch method.
Remote Controls
Figure A