21
This setup is for dual swing gates. A single button press of the remote control can open both gates.
This requires 2 gate operators. One gate operator is the "Primary", and the other is the "Secondary".
Dual Gate Setup
DATA-
DATA+
DATA-
DATA+
Figure 2
Electrical Conduit
Figure 1
1. On the Secondary gate operator circuit board, set dip switch #5 to ON (Figure 1).
2. Press the reset button on the Secondary gate operator circuit board.
3. A 20 gauge (or higher) 2 conductor electrical wire is required.
4. Locate the DATA- and DATA+ green terminal on the bottom left of the circuit board. (Figure 2). Use
a flathead screwdriver to release the 2 locks on the top of the green terminal.
5. Using the electrical wire, connect the DATA+ on the primary gate opener, to the DATA+ on the
secondary gate opener. Connect the DATA- on the primary gate opener to the DATA- on the
secondary gate opener. The M/S link LED light should now be lit on both circuit boards.
6. Use the flathead screwdriver to close the two locks on the top of the green terminal.
7. Place the cable underground in an electrical conduit. This conduit must separate from the main
110-120V AC electricity conduit.
8. Make sure all remote controls, photocell sensors, loop detectors, and any other accessories are
installed on the PRIMARY gate operator only. Only one photocell sensor is required. Finished.