User Manual
2253i / 2253iX
AMETEK
California Instruments
14
2.1.2 Output
Output Parameter
Specification
Model
2253i
2253iX
Modes
AC, DC
AC, DC, AC+DC
No of Outputs
3 standard
1 or 3 with –MODE option
Voltage
Ranges (L-N):
AC, AC+DC Mode
Low Vrange:
0 - 150 Vrms
High Vrange:
0 - 300 Vrms
DC Mode
Low Vrange:
0 - 200 Vdc
High Vrange:
0 - 400 Vdc
Programming Resolution:
0.1 V
Accuracy:
(ALC mode ON)
0.1% FS
1
(from 5V to FS
1
)
Distortion THD
2
:
< 1 %
16 - 1000 Hz
(harmonics and noise to 300 kHz)
Load Regulation:
(ALC mode ON)
0.1 % FS
1
(At external sense connection with ext sense mode programmed.)
Voltage Sense modes:
Internal
External
External Sense
Up to 3 % of set voltage can be dropped across each load lead.
Line Regulation:
0.02% for 10% input line change
DC Offset Voltage:
(In AC mode)
< 20.0 mV
Output Noise:
(20 kHz to 1 MHz, full R load)
< 100 mV
RMS
–
150V / 200V Range
< 200 mV
RMS
–
300V / 400V Range
Output Coupling
Direct coupled
Output Impedance (Z) (@
max current)
Z = Vrange * 0.001 / I_load
Current (with 200 – 230 VAC line input)
Output Mode
3 Phase
1 Phase
(-Mode)
AC Mode
High Voltage range
2.5 Arms @ 300 V
3.25 Arms @ 230 V
7.5 Arms @ 300 V
9.74 Arms @ 230 V
Low Voltage range
5.0 Arms @ 150 V
6.5 Arms @ 115 V
15.0 Arms @ 150 V
19.5 Arms @ 115 V
1
FS (Full Scale) refers to highest available range, e.g. 300Vac in AC mode, 400Vdc in DC mode.
2
The distortion specification applies at 77% voltage range, max current and resistive load conditions.
Содержание 2253i
Страница 5: ...User Manual 2253i 2253iX AMETEK California Instruments 5 SAFETY SYMBOLS...
Страница 99: ...User Manual 2253i 2253iX AMETEK California Instruments 99 Figure 6 1 Internal adjustment locations...
Страница 118: ...User Manual 2253i 2253iX AMETEK California Instruments 118 Figure 9 4 Voltage Modulation Frequency characteristics...