CALIFORNIA ACCENT LIGHTING, INC.
2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
5 / 20 / 2021 / Rev 3
Page 4 of 11
ALS
500T-DBR-HC
INSTALLATION INSTRUCTIONS
Mounting Luminaire (Aircraft Cable Assembly) 1 of 2
Unscrew & lift
Press down & hold
Pull cable
Aircraft Cable
Cable Gripper
Hex Nut
Flat Bracket
Hex Nut
Hex Head Bolt
Slide fixtures onto
Aircraft Cable Assemblies
Determine number of Aircraft Cable Assemblies required.
Note:
Refer to the diagrams on page 6 as a guide.
2
If applicable, assemble Aircraft Cable Assemblies. Install hex nuts about halfway
down each hex head bolt, then insert bolts through flat bracket and secure with
hex nuts.
3
Determine locations where Aircraft Cables will be mounted overhead. Secure to a
sturdy surface, such as studs, using hardware (by others) that is rated for the
weight of the luminaire.
Note:
Do not hang luminaire from weak material such as drywall or plywood.
4
Secure Aircraft Cable Assemblies to mounting surface. The top of the assembly
should rest approximately 7” above ceiling line. Ensure assembly is centered
between the T-Bars. Adjust position of assembly along aircraft cable using cable
gripper. Do not trim excess cable at this time.
5
Install concealed ceiling system grid. Assemble the grid so there is a continuous
6-1/2” opening where luminaires will be installed. There must be at least 10” of
overhead space from ceiling line to properly install luminaires.
Note:
Do not hang ceiling drywall before luminaires are installed. Luminaires
must be mounted prior to installation of ceiling to allow top access.
1
Adjust Cable Gripper by unscrewing locking mechanism. Press down and hold
the threads where cable feeds through. Pull cable from the exit. Let go of threads
to lock in place, then replace locking mechanism.
6
Slide luminaires onto Aircraft Cable Assemblies. Adjust positioning of lower hex
nut if needed to allow assemblies to slide in easily. Always install corners first.
7
If applicable, install end cap to end of run.
8
6-1/2”
Ceiling Line
10”
Projected Location of
Hard Ceiling Drywall
Aircraft Cable
Mounting Surface
Excess cable
~7”
Cable Gripper
Ceiling Line