ALS
500T-DBR-HC
INSTALLATION INSTRUCTIONS
Design Guidelines (Configurations)
LINEAR CONFIGURATION
8’
8’
3’6”
19’6”
End Cap
C
Standard Length
A
Custom Length
B
MITERED CONFIGURATION
8’
1’
1’
6’
8’
Standard Length
A
Custom Length
B
Mitered Corner
D
Mitered Corner
D
End Cap
C
JUMPER CONFIGURATION
8’
8’
Jumper Cable
E
Standard Length
A
End Cap
C
POWER DISTRIBUTION
Continuous Connection
G
Driver
F
Driver
F
To Power Source
To Power Source
Circuit #2
H
(White)
Circuit #1
H
(Gray)
KEY
A
Standard Length:
Luminaire runs are constructed in 8’ segments.
B
Custom Length:
Any required length that is not 8’. Typically the last
segment of a run.
C
End Cap:
Used to terminate a run.
D
Mitered Corner:
Standard 90° Mitered Corner. Custom angles available
upon request.
E
Jumper Cable:
Used to connect two luminaires with a gap between.
F
Driver:
The driver is typically mounted on top of the first luminaire
segment of a run. The driver may also be mounted elsewhere. Each run
typically has its own driver.
G
Continuous Connection:
Each luminaire segment is built with quick
disconnects to easily connect to the next segment in line.
H
Circuits:
Example U-Shaped run exceeds Max Run lengths and is split
into two circuits, each with their own driver. Max Run lengths vary by light
source. See individual light source specifications for details.