background image

CALIFORNIA ACCENT LIGHTING, INC.

2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com

© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.

5 / 20 / 2021 / Rev 3

Page 5 of 11

ALS

500T-DBR-HC

INSTALLATION INSTRUCTIONS

Mounting Luminaire (Aircraft Cable Assembly) 2 of 2

Tighten hex nuts

to secure in place

Lead Wire

After all luminaires have been mounted, secure Aircraft Cable Assemblies to 
luminaire by tightening lower hex nuts. All aircraft cables must rest in a vertical 
position. Do not allow aircraft cables to rest at a slant or angle. Adjust as needed.

Note:

 The position of the Aircraft Cable Assemblies may deviate from the

spacing diagrams on page 6 due to variations within the installation area. 
Ensure all luminaires are appropriately balanced.

9

Make wiring connections from driver to 1st PCB. Pull lead wires from luminaire 
and make splice connections to lead wires from driver. Verify wiring diagram 
before connecting.

15

Perform a continuity test before connecting luminaire to power source.
Refer to page 10 for continuity test step by step.

16

Verify driver wire colors from wiring diagram, then connect luminaires to power 
source. Drivers used for this product vary. Always confirm wiring diagram from 
driver installation instructions before connecting.

17

If applicable, install mud-in end cap at end of run. The mud-in end cap is used 
when the end of the luminaire terminates at drywall. Cut a hole in the drywall 
where luminaire opening will be present. Only the main extrusion should be 
exposed. Install mud-in end cap using countersink screws and ensure it is flush 
with drywall. Apply mud to create a smooth, even surface.

14

If applicable, position the driver in the center of luminaire and secure using set 
screws (by others). Do not mount drivers between luminaires.

Note:

 Driver size and location of mounting holes may differ from below example.

13

Secure connections between continuous runs using Connector Blocks after all 
luminaires have been mounted.

Note:

 Refer to steps on page 7 for details.

10

After all luminaires are mounted, adjust height and levelness of each luminaire 
by adjusting cable gripper. Use a dummy piece of drywall to perfect the height at 
which the luminaires will rest. The drywall will be tucked into the gap between 
the Hard Ceiling Trim and the concealed ceiling grid when hung.

Note:

 One person holds the luminaire and another person adjusts cable gripper.

12

Install Ceiling Trim after all luminaires have been mounted and connected. 

Note:

 Follow the steps on page 8 to install Ceiling Trim.

11

Hard Ceiling Trim flush with

projected location of ceiling drywall

Ceiling Line

Adjust length as needed

Trim excess cable

Содержание alumLEDs ALS500T-DBR-HC

Страница 1: ...ing 24 Volts DC for easy and safe installation Long life energy efficient LEDs Available in 4 Watts up to 24 Watts Per Foot Can be ordered to specific lengths for when exact dimensions are known Examp...

Страница 2: ...o Power Source Circuit 2H White Circuit 1H Gray KEY A Standard Length Luminaire runs are constructed in 8 segments B Custom Length Any required length that is not 8 Typically the last segment of a run...

Страница 3: ...to make changes or withdraw specifications without prior notice 5 20 2021 Rev 3 Page 3 of 11 ALS500T DBR HC INSTALLATION INSTRUCTIONS Diagram of Assembly Aircraft Cable Hard Ceiling Hard Ceiling Trim...

Страница 4: ...such as drywall or plywood 4 Secure Aircraft Cable Assemblies to mounting surface The top of the assembly should rest approximately 7 above ceiling line Ensure assembly is centered between the T Bars...

Страница 5: ...ct vary Always confirm wiring diagram from driver installation instructions before connecting 17 If applicable install mud in end cap at end of run The mud in end cap is used when the end of the lumin...

Страница 6: ...5 Aircraft Cable Assembly 4 ALS500T DBR 6 8 Aircraft Cable Assembly 4 For luminaires 1 5 long use 2 Aircraft Cable Assemblies per luminaire Install each assembly about 4 from each end of luminaire No...

Страница 7: ...lade for cutting metal Note If applicable remove Connector Blocks from extrusion before cutting 1 Position luminaires together and align the screw of the Male Block to meet the Female Block Tighten Al...

Страница 8: ...ween trim and fixtures not aligned Install Trim Retention Springs to ceiling trim Use one clip per 2 or two clips per segment under 4 Install clips 4 from each edge evenly spaced 3 Measure and cut a 2...

Страница 9: ...ate how much more film will be needed Make small cuts at the end of the film and test fit it Repeat if necessary until the film meets the end cap flush 5 Check along entire run that Reflective Film is...

Страница 10: ...ath is formed between the positive and negative wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify the malfunction in the line If there is no conductive path the multimeter w...

Страница 11: ...ctory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion as a ra...

Отзывы: