![Calian SatService sat-nms ACU2-19V2 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/calian/satservice-sat-nms-acu2-19v2/satservice-sat-nms-acu2-19v2_user-manual_3410483045.webp)
The RCPH19 is very simular to the RCPH, but mounted in a 1RU 19 Inch rack drawer. Have a
look to the previous chapter for the description.
Remark: Requires RCPH-UP for sat-nms ACU-ODU-xx to realize the interconnection.
Startup
Set parameter 'RS485 address' on the ACUs Setup-page to 'TERM'. This enables communication
between the ACU and the sat-nms handheld.
Connect the Handheld with the provided cable (Handheld: 9pol DSUB + Power supply, ACU-
Cabinet: 15pol DSUB). After connecting the Handheld, push the Redraw button once. The start-
up screen, that shows the installed software version is displayed for a few seconds. After that the
menu for controlling the antenna is displayed automatically.
Operation
--- Emergency STOP, stops all Motors immediately, it has to be released by
pushing the -button
--- Releases the motor-lock that was set by pushing the STOP-button.
--- Back to start screen
--- Turns the polarisation counterclockwise
--- Selects the step-size: small steps: x??/keypress (x is the value that was set
on the setup-screen), large steps: 10*x??/keypress, continuous mode: the antenna moves
as long until the -button is pushed or a limit switch or limit value is reached.
--- Turns the polarisation clockwise
(C) 2022, SatService GmbH
www.satnms.com
ACU2-19V2-UM-2209 Page 44/99