The ACU Linear (LP)/ Circular(CP) Switch interface is designed to control the mode switching of
an antenna by providing a switch command via relay output and indication inputs via
optocouplers. The indication polarity (NC or NO) can be defined in the ACU setup.
When connecting a CP/LP Switch to the ACU, please consider the following:
The relay outputs are designed for 30VDC/ 2A maximum.
If the load for the output is inductive, please don't forget the free-wheeling circuit.
The optocoupler inputs are designed for 24V only, with an input current of about 10mA.
pin
signal
description
type
1
CP Cmd COM
CP Command Common
IN
2
CP Cmd OUT
CP Command Output
OUT
3
LP Cmd COM
LP Command Common
IN
4
LP Cmd OUT
LP Command Output
OUT
5
n.c.
not connected
6
CP Ind A
CP Indicator Anode
IN+
7
CP Ind K
CP Indicator Cathode
IN-
8
LP Ind A
LP Indicator Anode
IN+
9
LP Ind K
LP Indicator Cathode
IN-
J16, J17 RS422
Connector Type: D-Sub9 female
J16, J17 provides the interface to the external Handheld LCPD (or GD Satcom PMCU with
Display)
pin
signal
description
type
1
RS422 GND
RS422 GND
OUT
6
RS422 Tx-
RS422Tx- Angle Info
OUT
19
RS422 Tx+
Angle Info
OUT
20
SHLD
Shield
J11 Digital Inputs
Connector Type: D-Sub25 male
The ACU provides digital auxiliary inputs for additional signal detection (e.g. Deice status, ..).
When connecting these Inputs to the ACU, please consider the following:
The optocoupler inputs are designed for 24V only, with an input current of about 10mA.
pin
signal
description
type
(C) 2022, SatService GmbH
www.satnms.com