7.8.6 Brew Group
Brew Chamber and Funnel
Frequency: weekly or every 200 cycles
1. Place a large cup or container under the dispensing
nozzle to collect the hot rinse water.
2. Perform several rinse cycles (see section 7.1).
3. Remove the brown tube from its support. Remove
the brew chamber funnel to expel+ coffee residue
trapped underneath it and rinse it under hot water.
4. Reinstall the funnel and the tube in its support.
Make sure the tube is against the wall of the funnel.
Water must form a circular motion when being
dispensed.
5. Order a large coffee to ensure that the brew
chamber is working properly.
Place a container large enough (size specified on the screen).
Water is VERY HOT.
Crush hazard. Handle the brew group cautiously.
Brew Group Assembly
Frequency: monthly or every 1,000 cycles
In order to maintain optimal performance of the brew group
assembly, it is recommended to remove it from the unit, clean
it and rinse it under hot water.
1. Open the brewer’s door and remove the front panel.
2. Cut the filter paper with scissors on both sides of the
brew chamber.
3. Remove the waste bin.
4. Remove the black plastic spout from the brew group
spillway.
5. Push the locking pin down to release the brew group,
then on the right to keep it unlocked. Pull the brew
group out.
6. Rinse the brew group thoroughly under hot water to
remove visible soil.
7. Remove the funnel from the brew chamber and rinse it
thoroughly under hot water.
8. Air dry completely before reinstalling the parts.
9. Order a large coffee to ensure that the brew group is
working properly.
The brew group assembly can also be cleaned using urn
cleaner. See section 7.2 for cleaning instructions.
Brew
chamber
Funnel
Tube retainer
Locking pin