EN1805CMINSA Rev. 5 2021-10
www.cafection.com 800-561-6162
60
SERVICE & INSTALLATION MANUAL - Encore 29
7.8.4 Soluble Canisters
Frequency: monthly or every 1,000 cycles
It is recommended to remove, empty and
clean the soluble canisters every month to
avoid powder to accumulate on the walls
of the canisters and alter the quality of the
beverages.
1. Open the brewer’s door.
2. Lift the hood and pull the canisters out of
the brewer.
3. Clean and sanitize under hot water and air
dry completely.
4. Reinstall all parts and reload products in
the canisters.
5. Order a large beverage of each soluble
to confirm that all parts and switches are
working properly.
7.8.5 Soluble Whipper Assembly
Frequency: weekly or every 200 cycles
If there is product accumulation, remove the soluble whipper assembly for manual cleaning
under hot water.
1. Remove the tube and the plastic elbow from the base.
2. Twist off the whipper base counterclockwise to unlock the whipper chamber.
3. Pull the whipper chamber outward, then remove the whipping disk.
4. Clean all parts and gaskets with hot water. Use a small brush if necessary.
5. Air dry completely.
6. Reinstall all parts in reverse order. Make sure the whipper base is on lock position.
7. Order a large beverage of each soluble to ensure that all parts and switches are
working properly.
Whipper base
Whipping
chamber
Funnel cover
Whipping disk
Gasket
Whipper base
C
le
an
in
g
an
d
San
it
iz
in
g