Trigger Button:
enable or disable. By default, the
Trigger Button
is disabled. You can change the default
value using the drop-down menu. Through this option you can enable/disabled the tag inventory at the
press of the trigger button of the reader. When the
Trigger Button
is enabled, to perform the tag inventory
just hold down the trigger button and then release.
Note:
In the easy2read profile, in order to enable the tag inventory on button press, it is
necessary to perform a second activation via software:
-
Using the Easy controller Software:
for more details see §
or
-
Using the API:
for more details see the
EventInventoryTag
Method
(the
event trigger flag
, bit
5, set to 1) in the
CAEN RFID API Reference Manual
downloadable from
, Documents
section or in the
web area.
Proximity Sensor Trigger:
enable or disable. By default, the
Proximity Sensor Trigger
is disabled. You can
change the default value using the drop-down menu. When the
Proximity Sensor
is enabled, the reader
performs a tag inventory when he perceives a decrease in brightness due to the passage of a tag. Note that
the sensor is also sensitive to the change in brightness due to the turning off of the light or the passage of a
shadow.
Note:
In the easy2read profile, in order to enable the proximity sensor, it is necessary to perform
a second activation via software:
-
Using the Easy controller Software:
for more details see §
or
-
Using the API:
for more details see the
EventInventoryTag
Method
(the
event trigger flag
, bit
5, set to 1) in the
CAEN RFID API Reference Manual
downloadable from
, Documents
section or in the
web area.
Tag ID Beep:
enable or disable. By default, the
Tag ID beep
is disabled. You can change the default value
using the drop-down menu. If the
Tag ID beep
is enabled, the reader will beep when a tag is detected.
Tag ID Lights:
enable or disable. By default, the
Tag ID lights
are disabled. You can change the default value
using the drop-down menu. If the
Tag ID Lights
are enabled, the reader will lights up when a tag is detected.
Tag Count:
enable or disable. By default, the
Tag Count is
disabled. You can change the default value using
the drop-down menu. If the Tag Count is enabled, when the reader performs a tag inventory, the reader
display shows the number of read tags.
Warning:
To save the changes click on the “
SAVE
” button. Note that all changes made via the web
interface are active only after the reboot of the reader. Click on
SYSTEM
option in the Web Interface panel
and then click on the “Reboot” button. After reboot, the new settings are active.