The correspondent values are:
Percentage
Conducted Power
1
(mW)
Radiated Power ETSI
(mW e.r.p.)
Radiated Power FCC
(mW e.r.p.)
5%
25
16
18
10%
50
32
36
20%
100
64
72
40%
200
128
144
60%
300
192
215
80%
400
256
287
100%
500
320
359
Tab. 3.2: Conducted power- radiated power
Note that, when the reader is configured in the easy2read profile, to set the power you can also use the
CAEN RFID Easy Controller Application or the
SetPower
function of the SDK (Software Development Kit)
library.
Trigger Button:
through this option, you can enable/disable the tag inventory on trigger button press. By
default, the Trigger Button is disabled. To modify the value, press the
trigger
button until the desired value
is shown (enabled/disabled), then press the
up or down
button to select “back” and the
trigger
button to
return to the RFID submenu. When the
Trigger Button
is enabled, to perform the tag inventory just hold
down the trigger button and then release.
Note:
In the easy2read profile, in order to enable the tag inventory on button press, it is
necessary to perform a second activation via software:
-
Using the Easy controller Software:
for more details see §
or
-
Using the API:
for more details see the
EventInventoryTag
Method
(the
event trigger flag
, bit
5, set to 1) in the
CAEN RFID API Reference Manual
downloadable from
, Documents
section or in the
web area.
Proximity:
through this option, you can enable/disable the proximity sensor (see §
page 7). By default, the
Proximity Sensor
is disabled. To modify the value, press the
trigger
button
until the desired value is shown (enabled/disabled), then press the
up or down
button to select “back” and
the
trigger
button to return to the RFID submenu. If the
Proximity Sensor
is enabled, the reader performs a
tag inventory when he perceives a decrease in brightness due to the passage of a tag. Note that the sensor
is also sensitive to the change in brightness due to the turning off of the light or the passage of a shadow.
Note:
In the easy2read profile, in order to enable the proximity sensor, it is necessary to perform
a second activation via software:
-
Using the Easy controller Software:
for more details see §
or
-
Using the API:
for more details see the
EventInventoryTag
Method
(the
event trigger flag
, bit
5, set to 1) in the
CAEN RFID API Reference Manual
downloadable from
, Documents
section or in the
web area.
Tag ID Beep:
by default, the
Tag ID beep
is disabled. To modify the value, press the
trigger
buttons until the
desired value is shown (enabled/disabled), then press the
up or down
button to select “back” and the
trigger
button to return to the RFID submenu. If the
Tag ID beep
is enabled, the reader will beep when a tag
is detected.
Tag ID Lights:
by default, the
Tag ID lights
are disabled. To modify the value, press the
trigger
buttons until
the desired value is shown (enabled/disabled), then press the
up or down
button to select “back” and the
trigger
button to return to the RFID submenu. If the
Tag ID Lights
are enabled, the reader will lights up
when a tag is detected.
Tag Count:
by default, the Tag ID Count is disabled. To modify the value, press the trigger buttons until the
desired value is shown (enabled/disabled), then press the up or down button to select “back” and the
1
On external antenna