User’s Manual
Aquavision Control
Monitoring Module
Flow detected with valve
closed
Alarm if the valve can no longer fully close
Unstable pressure
measured with valve
closed
Alarm if a loss of pressure is measured when the shut-off valve is
closed. This can indicate a very small leak in the pipe.
Alarm period no
consumption
Alarm report that can indicate a faulty connection with the water
meter.
Water pressure out of
range of pre-set limits
Alarm signal when the pressure exceeds or falls below the pre-set
minimum or maximum limits
Temperature out of
range of pre-set limits
Alarm signal when the temperature exceeds or falls below the pre-set
minimum or maximum limits
Unlimited water
consumption activated
Report if the "Unlimited water consumption" mode is activated.
Manual valve closure
Report if a valve is closed by the user via a manual activation on the
module screen
Intrusion alarm active
Report if the intrusion alarm was activated
Alarm main water pipe
Report when a leak is observed between the street and the building.