WALL -TILE - MOON - LEAN
8
Fig. 9 - Cut- Removal
Fig. 10 - Connections
How to connect to the stove in the sealed chamber with concentric system:
• Insert the N fitting into the I air intake pipe (see
). Connect N to Q using a flexible tube which can resist a
temperature of 100°C (a flexible aluminium tube is recommended).
• Maximum height for the installation of a vertical exhaust flue (roof) HV = 6 mt (see
).
• Maximum height for the installation of a horizontal exhaust flue (wall) HO = 2.6 mt (see
).
Fig. 11 - Flexible tube
Fig. 12 - Connections
Fig. 13 - Flue connections
LEGEND
I
Combustion air intake with a diameter of 40 mm
N
Rubber fitting with a diameter of 40/60 mm
R
Flexible aluminium tube
Q
Coaxial pipe air combustion connection
Y
Coaxial pipe air combustion intake
HO
Height of coaxial flue with wall/horizontal exhaust
HV
Height of coaxial flue with roof/vertical exhaust