WALL -TILE - MOON - LEAN
12
This operation
(1*)
must be performed by a technician qualified to disconnect the combustion product expulsion ducts and their
subsequent restoration.
For generators connected to the hydraulic system, a connection must be provided between the system itself and the product so
that, during extraordinary maintenance, carried out by a qualified technician, it is possible to move the generator 1 by at least 50
cm from adjacent walls without emptying the system (e.g. by using a double shut-off gate or suitable flexible connection).
(1*)
The national reference standard for the installation of domestic appliances is UNI 10683 (IT) - DTU NF 24.1 (FR) - DIN 18896
(DE) - NBN B 61-002 (BE) - Real Decreto 1027/2007 (ES) Paesi Bassi (NL) Bouwbesluit - Danmark (DK) BEK n° 541 del 27/04/2020.
6.3
WALL MOUNTING
The stove is suitable for wall mounting. The can be attached to a load-bearing wall in masonry (NOT plasterboard, wood, etc...)
suitable for the entire weight of the stove.
Fig. 16 - Wall mounting
LEGEND
1
Stove
2
Minimum lateral distance = 300 mm
3
Minimum front distance = 1000 mm
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides
to enable an eficient appliance cooling and a good distribution of heat in the room (see
).
In some countries also masonring load-bearing walls are considered flammable.
If you want to fix the stove to a non-flammable material wall, you need to fix the support to the wall (the support is provided with
the stove).
• Call an expert to prepare the fumes outlet hole and the combustion air inlet hole.
• To fix the rear support to the wall with metal plugs su1itable for the weight of the stove (see
).
Fig. 17 - Mounting on non-flammable wall