89CD220020EN
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION
REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE)
Manufacturer
CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
Trademak: model identifier
CADEL: IDRO PRINCE 30
Description
Pellet stove
Indirect heating functionality
YES
Direct heat output
1,7 kW
Indirect heat output
26,9 kW
CPR harmonised standard
EN 14785
Notified body
KIWA CERMET ITALIA S.P.A.(N.B.0476)
Preferred fuel (unique)
Compressed wood with moisture content < 12 %
YES
Wood logs with moisture content ≤ 25 %
NO
Other woody biomass
NO
η
s
83
%
EEI
125
-
Energy Efficiency Class (A++ to G scale)
A+
Space heating emissions at nominal heat output
PM (al 13% O
2
)
18
mg/Nm
3
OGC (al 13% O
2
)
2
mg/Nm
3
CO (al 13% O
2
)
104
mg/Nm
3
NO
x
(al 13% O
2
)
127
mg/Nm
3
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
PM (al 13% O
2
)
21
mg/Nm
3
OGC (al 13% O
2
)
6
mg/Nm
3
CO (al 13% O
2
)
223
mg/Nm
3
NO
x
(al 13% O
2
)
98,6
mg/Nm
3
Heat output
Nominal heat output (P
nom
)
28,6
kW
Minimum heat output (indicative) (P
min
)
7,7
kW
Useful efficiency (NCV as received)
Useful efficiency at nominal heat output (η
th,nom
)
93,6
%
Useful efficiency at minimum heat output (indicative) (η
th,min
)
94,7
%
Auxiliary electricity consumption
At nominal heat output (el
max
)
0,115
kW
At minimum heat output (el
min
)
0,060
kW
In standby mode (el
sb
)
0,004
kW
Type of heat output/room temperature control (select one)
Single stage heat output, no room temperature control
NO
Two or more manual stages, no room temperature control
NO
With mechanic thermostat room temperature control
NO
With electronic room temperature control
NO
With electronic room temperature control plus day timer
NO
With electronic room temperature control plus week timer
YES
Other control options (multiple selections possible)
Room temperature control, with presence detection
NO
Room temperature control, with open window detection
NO
With distance control option
NO
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable) (P
pilot
)
N.A.
kW
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product.
Issue date: 18.11.2021