IDROSTUFE
12
h - Pump On T
This menu item allows to adjust the pump activation temperature.
To select the Pump On T function act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to confirm.
• Scroll to “Pump On T” using the arrows.
• Press “menu” to confirm.
• Modify the °C with the + - keys.
• Press “menu” to confirm and “esc” to exit
i - Auxiliary boiler
An additional (optional) module must be installed to allow an auxiliary boiler to be switched on should the stove be off or in alarm
conditions. By default, this function is disabled; if necessary, activate it through the settings menu.
j - Pellet Recipe
This function is for adapting the stove to the pellets that are being used. In fact, as there are several types of pellets on the market,
boiler operation is extremely variable depending on the fuel quality. In the event the pellets tend to clog the brazier due to an
excessive load of fuel or in the event the flame is always high even at low powers and, vice versa if the flame is low one can decre-
ase/increase the amount of pellets in the brazier:
The available values are:
-3 = Decrease by 30% compared to factory settings.
-2 = Decrease by 20% compared to factory settings.
-1 = Decrease by 10% compared to factory settings.
0 = No variation.
1 = Increase by 5% compared to factory settings.
2 = Increase by 10% compared to factory settings.
3 = Increase by 15% compared to factory settings.
To change the recipe act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to confirm.
• Scroll to “Pellet recipe” using the arrows.
• Press “menu” to confirm.
• Modify the % with the + - keys.
• Press “menu” to confirm and “esc” to exit
k - Smoke rpm % ventilation
If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion
speed can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits
forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are
from -30% to +50% with variations of 10 percentage points at a time. The variation in negative can be used in case the flame is
too low.
To change the parameter act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to confirm.
• Scroll to “Smoke rpm variation” using the arrows.
• Press “menu” to confirm.
• Modify the % with the + - keys.
• Press “menu” to confirm and “esc” to exit
l - Maximum power
It allows to set the maximum flame limit at which the boiler can operate to reach the set temperature target.
To change the power act as follows:
• Press the “menu” button.