15
IDROSTUFE
• access the MENU,
• scroll to TIMER with the <> arrows,
• press the “Menu” key
• the system proposes “P1” (Press the <> keys for the subsequent timers P2,P3, P4, P5, P6)
• to activate “P1” press the “Menu” key
• press + - and select “ON”
• confirm with the “Menu” key
At this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu” key to confirm.
The next step proposes a shutdown time of 10 minutes above that set for start-up: press the + key and adjust the shutdown time,
confirm with the “menu” key.
Subsequently the system proposes the days of the week in which to activate or deactivate the previously set timer. With the - or +
key highlight with the white background the day in which one wishes to activate the timer and confirm with the “menu” key. If no
day of the week is confirmed as active, in turn the timer programme will not appear active in the status screen.
Continue to program the following days or press “ESC” to exit. Repeat the procedure to program the other timers.
P1
P2
on
off
day
on
off
day
08:00
12:00
mon
11:00
14:00
mon
Boiler on from 08:00 to 14:00
on
off
day
on
off
day
08:00
11:00
mon
11:00
14:00
mon
Boiler on from 08:00 to 14:00
on
off
day
on
off
day
17:00
24:00
mon
00:00
06:00
tue
Boiler on from 17:00 on monday to 06:00 on tuesday
9.7
NOTES FOR TIMER OPERATION
• Start-up with the timer always takes place with the last temperature and ventilation settings (or with default 20°C and V3
settings in the event they have never been changed).
• Start-up time ranges from 00:00 a 23:50
• If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
• A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00 of the next day:
the boiler stays on.
• A programme proposes a start-up and shutdown in times included within another timer programme: if the boiler is already on,
start will not have any effect, while OFF will switch it off.
• In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on automatically at
the next time set on the timer.
• In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at the time set on
the active timer.
9.8
SLEEP FUNCTION (MAIN MENU)
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must
switch off.
To set the Sleep function act as follows:
• Enter MENU
• Scroll to SLEEP with the <> arrows
• Press Menu
• With the + - keys adjust the desired shutdown time.