LEGENDA 

WHERE TO DISPOSE

MATERIALS

D. ELECTRIC AND ELECTRO-

NIC COMPONENTS

To be disposed of separately in authorised centres, as 

indicated in the WEEE directive 2012/19/EU and the 

relative national transposition.

Wiring, motors, fans, circulators, display panels, sen-

sors ignition plug, electronic cards, batteries.

E. METAL STRUCTURE

To be disposed of separately with metal                      -

F. COMPONENTS THAT CAN-

NOT BE RECYCLED

To be disposed of with mixed waste                

E.G.: Gaskets, rube piping, silicone or fibres, plastic.

G. HYDRAULIC COMPONENTS

Piping, fittings, expansion vessel, valves. If there are 

any, to be disposed of separately based on the mate-

rial they are made of:

Copper
Brass
Stainless steel
Other materials

INSTRUCTIONS FOR PACKAGING DISPOSAL

The material that the appliance’s packaging is made of must be managed correctly, in order to make collection, reuse, recovery 

and recycling easier, where possible.

The table below illustrates the possible components that the packaging is made of, and the relative instructions for correct dispo-

sal.

DESCRIPTION

CODE MATERIAL

SYMBOL

DIRECTIONS FOR COLLECTION

- WOOD BED

- WOOD CAGE

- WOOD PALLET

WOOD

FOR 50

SORTED waste collection
WOOD
Check with the competent body on 

how to dispose of this packaging at 

the recycling depot

- CARDBOARD BOX

- CARDBOARD CORNER

- CARDBOARD SHEET

CORRUGATED CARDBOARD

PAP 20

SORTED waste collection
PAPER
Check the instructions of the compe-

tent body

- APPLIANCE BAG

- BAG OF ACCESSORIES

- BUBBLE WRAP

- PROTECTIVE SHEET

- LABELS

POLYETHYLENE

LD PE 04

SORTED waste collection
PLASTIC
Check the instructions of the compe-

tent body

- POLYSTYRENE

- FOAM PEANUTS

POLYSTYRENE

PS 6

SORTED waste collection
PLASTIC
Check the instructions of the compe-

tent body

- STRAP

- TAPE

POLYPROPYLENE

PP 5

SORTED waste collection
PLASTIC
Check the instructions of the compe-

tent body.

- SCREWS

- STAPLES FOR STRAP

- FASTENING BRACKET

IRON

FE 40

SORTED waste collection
METAL
Check with the competent body on 

how to dispose of this packaging at 

the recycling depot

Содержание IDRO PRINCE3 12

Страница 1: ...TOVE EN 2020CADELsrl Allrightsreserved Tuttiidirittiriservati IDRO PRINCE3 12 16 23 23H2 O 30 30H2 O IDRO RIVER3 16 23 23H2 O AQUOS3 16 23 23H2 O IDRON 16 22 AIRTIGHT MIRA 16 22 TESIS 16 23 AIRTIGHT H...

Страница 2: ...requiredifcorrectionfactorsF 2 orF 3 areapplied PM al 13 O2 28 mg Nm3 OGC al 13 O2 7 7 mg Nm3 CO al 13 O2 138 mg Nm3 NOx al 13 O2 133 mg Nm3 Heat output Nominal heat output Pnom 16 2 kW Minimum heat o...

Страница 3: ...yrequiredifcorrectionfactorsF 2 orF 3 areapplied PM al 13 O2 28 mg Nm3 OGC al 13 O2 7 7 mg Nm3 CO al 13 O2 138 mg Nm3 NOx al 13 O2 133 mg Nm3 Heat output Nominal heat output Pnom 22 8 kW Minimum heat...

Страница 4: ...F 2 orF 3 areapplied PM al 13 O2 23 mg Nm3 OGC al 13 O2 12 mg Nm3 CO al 13 O2 475 mg Nm3 NOx al 13 O2 75 mg Nm3 Heat output Nominal heat output Pnom 11 8 kW Minimum heat output indicative Pmin 3 2 kW...

Страница 5: ...t Nominal heat output Pnom 28 6 kW Minimum heat output indicative Pmin 7 7 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 93 6 Useful efficiency at minimum heat o...

Страница 6: ...fers to highlight the main components that can be found in the device and indica tions on how to separate and dispose of them correctly when no longer used More specifically the electric and electroni...

Страница 7: ...le The table below illustrates the possible components that the packaging is made of and the relative instructions for correct dispo sal DESCRIPTION CODE MATERIAL SYMBOL DIRECTIONS FOR COLLECTION WOOD...

Страница 8: ...USERTRAINING 20 14 SAFETY DEVICES AND ALARMS 20 14 1 SAFETY DEVICES 20 14 2 PRESSURE SWITCH 20 14 3 SMOKETEMPERATURE PROBE 21 14 4 CONTACTTHERMOSTAT INTHE FUEL HOPPER 21 14 5 ELECTRICAL SAFETY 21 14 6...

Страница 9: ...o Design and where applicable Directives 2014 35 EU LowVoltage 2014 30 EU Electromagnetic Compatibility 2014 53 EU Radio Frequency 2011 65 EU ROhS Read carefully the instruction contained in this manu...

Страница 10: ...sing a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The electrical cable must not get in touch with the fume exhau...

Страница 11: ...ermore theproductmustbeinstalledandstartedbyspecialisedpersonnelwhomust whereprovided issueadeclarationof conformity of the plant and of the proper functioning of the product for the warranty to be va...

Страница 12: ...y market surveillance or inspections by third parties please consider the following warnings to reach the declared performance levels the product must perform an operating cycle of at least 15 20 hour...

Страница 13: ...and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local dealer to collect the waste electric or...

Страница 14: ...esponsible for injury to persons or damage to property or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation...

Страница 15: ...urance in the combustion chamber cannot be guarantee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxiou...

Страница 16: ...itched off N Chimney sweep function activated only when the boiler is switched on for field emissions test O System configuration P Season Q Technical menu NOTE Some of the items listed above cannot b...

Страница 17: ...oveandthe actual temperature the stove supplies Connect the wires from the external thermostat to points 1 2 on the stove terminal board Once the thermostat is connected it must be enabled Do so as fo...

Страница 18: ...1 Increase by 5 compared to factory settings 2 Increase by 10 compared to factory settings 3 Increase by 15 compared to factory settings To change the recipe act as follows Press the menu button Scrol...

Страница 19: ...tivated only when the boiler is on and with power output and heating operation power with parameters P5 with fan if present inV5 Any loading smoke ventilation percentage corrections must be taken into...

Страница 20: ...with a small flame and alternately Chrono of active Ecoactive TheminutesindicatingthecountdownfortheEcoStopareshownatthetopofthedisplay Theflamegoesinto P1andstaysthereuntiltheprogrammed Ecoshutdownt...

Страница 21: ...y 17 00 24 00 mon 00 00 06 00 tue Boiler on from 17 00 on monday to 06 00 on tuesday 9 7 NOTES FOR TIMER OPERATION Start up with the timer always takes place with the last temperature and ventilation...

Страница 22: ...NERAL WARNINGS Removeallcomponentsthatcouldburn manual variousadhesivelabels andanypolystyrene fromtheproductbrazierandglass Make sure the brazier is positioned properly and rests solidly on the base...

Страница 23: ...with the keys Press menu to confirm and esc to exit Fig 11 Display Note The full stop to the right of the ambient temperature shown in the control panel display upper right indicates the half degree...

Страница 24: ...air due to a reduced or clogged air intake duct Using smoke ducts that do not meet the installation standard requirements such to fail to ensure appropriate draft Partially obstructed chimney due to...

Страница 25: ...eassureyouthattheyarestoredindryplacesand faratleastonemeterfromthestoveand oranyothersourceofheat It is advisable to try different type of pellets available on the market and to choose that which giv...

Страница 26: ...attheenduserissatisfied Otherwise thereisthe risk the device will be used unsafely Explanation of the device and how it works Need to keep the device ventilated and issues that could arise otherwise F...

Страница 27: ...the boiler is powered again it goes back to the previous operating condition with the following procedure 18 It performs a cooling phase to the maximum 19 Performs a new ignition During stage 1 the p...

Страница 28: ...s running out in the hopper during the night PANEL ALERT TYPE OF PROBLEM SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper A02 The fire goes off a...

Страница 29: ...ume pipe chim ney flue and chimney pot cleaned at least once a year It is also necessary to have the combustion chamber motors and fans cleaned and to have the gaskets and the electronical elements ch...

Страница 30: ...e from the compartment before reinserting the drawer Experience and pellet quality will determine the frequency of the ash drawer cleaning In any case it is advisable not to exceed 2 or 3 days When cl...

Страница 31: ...tanttoalwaysmaintainthedecla red performance As such we recommend cleaning the internal exchanger every 2 3 days following these simple tasks in order Activate CLEANING function when the boiler is off...

Страница 32: ...ecialized stove repairer who will provide for the cleaning of fume pipe chimney flue and chimney pot He will also check their eficiency and will release a written declaration of the safety of the appl...

Страница 33: ...there are children we recommend removing the power cable alltogether When turning the stove back on if the control panel display does not turn on when you press the main switch on the side of the prod...

Страница 34: ...ing 16 IN CASE OF ANOMALY 16 1 PROBLEM SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetabl...

Страница 35: ...e stove stops Empty hopper Full the hopper Auger blocked by a foreign object for example nails Clean the auger Bad quality pellets Try other types of pellets Pellet drop value too low phase 1 Adjust t...

Страница 36: ...obstructed holes with too ash remains Have the fan blades and auger cleaned Obstructed exhaust The exhaust chimney is partially or totally obsturcted Contact an expert stove repairer who checks the st...

Страница 37: ...ature Reached fume outlet limit tempe rature The stove runs at minimum NO PROBLEM The smoke extrac tion motor is not working No power to the boiler Check the mains voltage and the protective fuse The...

Страница 38: ...robe Checkand ifnecessary replacetheprobe Defective or broken control panel Checkand ifnecessary replacethepanel The boiler does not start Power outage Make sure the power cable is plugged in and the...

Страница 39: ...ure Insufficient fuel consumption Checktherecipeand ortechnicalparameters Radiators cold in the winter Room thermostat local or remote adjusted too low If remote thermo stat check whe ther it is defec...

Страница 40: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 Rev 00 2022 www cadelsrl com www free point it www pegasoheating com...

Отзывы: