Remove and empty ash pan “D”. Wipe away any residual ash before reinserting the pan. Your experience and the quality of the
pellets will determine the ash pan cleaning frequency. However, it is recommended not to exceed 7 days. After removing and
emptying the ash pan “D” also clean the lower part of the compartment (see arrow “Q”).
Fig. 20 - Brazier removal
Fig. 21 - Drawer removal
Attention! When cleaning is completed, remember to put part “C”, brazier “B” and ash pan “D” back in place
and close all the doors (“G”, “H”, “F”)back up again.
15.6 CLEANING THE GLASS
It is recommended to clean the ceramic glass with a dry brush, or if it is very dirty, spray a little specific detergent and clean with
a cloth.
ATTENTION!
Do not use abrasive products and do not spray the glass spray cleaner on the painted parts or the door gaskets
(ceramic fibre cord).
15.7 CLEANING THE EXCHANGER AND THE COMPARTMENT UNDER THE BRAZIER EVERY 2/3 DAYS
Cleaning the exchanger and the compartment under the brazier is a simple task but very important to always maintain the decla-
red performance.
As such, we recommend cleaning the internal exchanger every 2-3 days, following these simple tasks in order:
•
Activate “CLEANING” function
- when the boiler is off, press - menu, select “Settings”, use the <> arrows to select “Clea-
ning”, confirm with “Menu”, active cleaning “ON” using the +- keys. This procedure activates the smoke extraction fan to the
maximum, in order to expel the soot that is stirred up while cleaning the exchanger.
•
Clean the pipe unit
- Using lever “A”, located under the tank cover, vigorously shake the turbulators 5-6 times. This removes
the soot deposited on the exchanger smoke ducts during normal boiler operation.
•
Disable the “CLEANING” function
- this function is automatically disabled after two minutes. If you need to stop this fun-
ction sooner, press the “Esc” key.
•
Clean the smoke conveyor compartment
(fig. on next page)
• The boiler is equipped with a removable ash drawer to collect any soot and ash build-up (previous page).
• Once cleaning is complete, close the cover and ash drawer.
If this cleaning is not done every 2-3 days, the stove could become clogged with ash after several hours of
operation and go into alarm conditions.