It should be noted that higher I/O counts are possible by using more than two MegaCOMMS units; this
can be achieved with a Cadac CDC MC Router. The CDC MC Router can handle up to 3072 channels.
20: CDC MC Router
Note that the number of any connector on a stagebox is unrelated to its function. Any input (or output)
connector can be assigned in software to a system input (or output) of any type
– channel input, aux
send, channel insert, matrix output, etc.
– anywhere in the console’s architecture. It should also be
noted that the overall I/O physical connectivity provided by the system is unrelated to the CDC five
’s
maximum processing capacity of 48 simultaneous input channels mixing onto 24 assignable output
busses. Some additional connectors will be required in all installations for channel or bus insert sends
and returns, and for ‘B’ inputs to input channels.
Routing
Routing is done using the on-screen Input and Output Assign functions.
21: CDC five Routing Screen