USING BRIDGE MANAGEMENT OPTIONS
5-17
3. Highlight the Port 1 Poll Address field.
4. Enter the Ethernet address of the Repeater Module installed in the
MMAC 2 in a hex XX-XX-XX-XX-XX-XX format.
5. Press Return. If the Ethernet address was entered in an improper hex
format, the message "Illegal Ethernet Address Entered" will appear at
the top left of the screen.
6. Enter the poll interval, in seconds, into the Port 1 Poll Interval field. A
time of 1 to 30 seconds may be entered.
7. Press Return. If the poll interval was entered as O seconds, the
message "Numeric Entry Must be Greater Than or Equal to 1" will
appear at the top left of the screen. If the poll interval was entered as
more than 30 seconds, the message "Numeric Entry Must be Less
Than or Equal to 30" will appear.
8. Enter the maximum retry interval, in seconds, into the Port 1 Max
Retries field. A retry count of 2 to 99 may be entered.
9. Press Return. If the retry count was entered as 1 or less, the message
"Numeric Entry Must be Greater Than or Equal to 2" will appear at the
top left of the screen.
10. Enter the Ethernet address of the Repeater Module installed in the
MMAC 1 in a hex XX-XX-XX-XX-XX-XX format.
11. Press Return. If the Ethernet address was entered in an improper hex
format, the message "Illegal Ethernet Address Entered" will appear at
the top left of the screen.
12. Repeat steps 6-9 for the Port 2 Poll Interval and Port 2 Max Retries
fields.
13. Highlight the EXECUTE option button at the bottom of the Port
Setup Screen.
14. Press Return. The message "Port Setup Screen Parameters Saved"
will appear and the redundancy function will be enabled.
Содержание NB30
Страница 2: ......
Страница 4: ...NOTICE ii ...
Страница 10: ...INTRODUCTION 1 4 ...
Страница 20: ...USING LOCAL MANAGEMENT 3 4 ...
Страница 30: ...BRIDGE INFORMATION SCREEN 4 10 ...
Страница 78: ...USING BRIDGE MANAGEMENT OPTIONS 5 48 Table 5 1 Optimal Bridge Max Age Parameters ...
Страница 84: ...USING BRIDGE MANAGEMENT OPTIONS 5 54 ...
Страница 88: ...Appendix A A 4 ...