BRIDGE INFORMATION SCREEN
4-5
The status/alarm messages for the Remote Port are:
DSVESF and DS1/D4 Module Port Status Messages
NORMAL
The port is in normal T1 Link operation.
NET LOOP
The port is looped towards the network.
REM LOOP
The port is performing a remote loopback test.
DS1/ESF and DS1/D4 Module Port Alarm Messages
LINK OK
Indicates that the port is ready for transmission.
LOST SIGNAL
Indicates that the Remote port is not receiving any
signal, probably due to an unplugged cable .
YELLOW ALARM
Indicates a loss of synchronization has occurred on
the receive link of the NB30 on the other side of
the Remote link.
RED ALARM
Indicates a loss of synchronization has occurred on
the receive link of the bridge.
RS449 and V.35 Module Port Status/Alarm Messages
NO EXT CLOCK
Indicates that the Remote port is not
receiving a clock signal from the DCE.
DCE NOT READY/NO DM Indicates that the DCE is not in the data
transfer mode
DCE NOT READY/NO CTS Indicates that the DCE is not ready to
transmit data.
LINK OK/ DCE READY
Indicates that communication between
the Remote port and the DCE is
established, and they are ready to transfer
data.