EPIM SPECIFICATIONS
Page A-18
b.
Verify that the fiber strands are properly “crossed over”
between the applicable port on the module and the fiber optic
device at the other end of the fiber optic link segment.
c.
Verify that the fiber connection meets the dB loss specifications
outlined in Fiber Optic Network Requirements.
If a link still has not been established, contact Cabletron Systems
Technical Support.
A.3.4
Connecting a Thin-Net Segment to an EPIM-C
To connect a thin-net segment to an EPIM-C:
1.
Set the Internal Termination Switch, located to the right of the port
and labeled TERM to:
•
The on position (•) if the thin-net segment connected directly to
the port will be internally terminated at the port.
•
The off position (o) if the thin-net segment will not be
terminated at the port or externally terminated.
2.
If the Internal Termination switch is in the On position, connect
the thin-net segment directly to the BNC port as shown in
Figure A-9.
3.
If the Internal Termination switch is in the Off position:
a.
Attach a BNC tee-connector to the BNC port on the module.
b.
Attach the thin-net segment to one of the female connectors on
the tee-connector.