Model 256/PC Instruction Manual
Page 7
250mA/250V
CAUTION!
For continued protection against
risk of fire, replace only with
same type and rating of fuse.
FOOTSW ITCH
P R O B E
E N A B L E
P R IN T E R /S E R IA L
J 2
J 4
1 2 7
1 2 8
2 5 5
2 5 6
6 5
6 6
6 4
6 3
1 9 3
1 9 4
1 9 1
1 9 2
1
2
1 2 9
1 3 0
J 1
J 3
4
2,
6
SEQ.
BUILD
RANDOM
BUILD
ERROR
LIST
TEST
RESET
MENU
RUN
MODEL 256
1
3,
5
1. Load program (Figure 8).
2. Connect harness to be tested.
3. Press TEST, and the Model 256/PC will perform one test scan.
4. For a successful test, the display will show:
Passed XXXX/YYYY
Where XXXX is the number of tests that have passed and YYYY is the number of tests
that have been run. Loading the program sets these numbers to zero. If an error is found,
display will show O for open or S for short, with From/To points.
5. To continue test beyond failed points, press TEST again.
6. When testing is finished, disconnect harness.
NOTE
If a hard copy of test errors is required, use ERROR LIST (Figure 10).
Figure 5. Simplified TEST Procedure (Single Test)
Содержание 256/PC
Страница 1: ...MODEL 256 PC CONTINUITY TESTER ...
Страница 2: ......
Страница 61: ...Model 256 PC Instruction Manual Page 53 Figure 20 Schematic CPU Board 1 of 3 ...
Страница 62: ...Page 54 Model 256 PC Instruction Manual Figure 20 Schematic CPU Board 2 of 3 ...
Страница 63: ...Model 256 PC Instruction Manual Page 55 Figure 20 Schematic CPU Board 3 of 3 ...
Страница 64: ...Page 56 Model 256 PC Instruction Manual Figure 21 Schematic Scanner Board 1 of 3 ...
Страница 65: ...Model 256 PC Instruction Manual Page 57 Figure 21 Schematic Scanner Board 2 of 3 ...
Страница 66: ...Page 58 Model 256 PC Instruction Manual Figure 21 Schematic Scanner Board 3 of 3 ...
Страница 67: ...NOTES ...
Страница 68: ...Cablescan 5900379 REV G ...