54
54
Rev. A
If the time-out period expires before a high priority symbology is read, the imager will read any
barcode
in its view (low priority or unspecified). If there is no barcode in the imager’s view
after the time-out period expires, then no data is reported.
Note: A low priority symbol must be centered on the aiming pattern to be read
Scan a barcode below to enable or disable Preferred Symbology.
Preferred Symbology On
* Preferred Symbology Off
High Priority Symbology
To specify the high priority symbology, scan the High Priority Symbology barcode below. On
the Symbology Chart, find the symbology you want to set as high priority. Locate the Hex value
for that symbology and scan the 2 digit hex value from the Programming Chart (inside back
cover). Scan
Save
to save your selection. Default = None
High Priority Symbology
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology barcode below. On the
Symbology Chart, find the symbology you want to set as low priority. Locate the Hex value for
that symbology and scan the 2 digit hex value from the Programming Chart (inside back
cover).
If you want to set additional low priority symbologies, scan
FF
, then scan the 2 digit hex value
from the Programming Chart for the next symbology. You can program up to 5 low priority
symbologies. Scan
Save
to save your selection. Default = None
Low Priority Symbology
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low priority
symbologies, you must set the time-out period. This is the period of time the imager will
search for a high priority barcode after a low priority barcode has been encountered. Scan the
barcode below, then set the delay (from 100-3,000 milliseconds) by scanning digits from the
inside back cover, then scanning
Save
. Default = 500 ms.
Preferred Symbology Time-out
Preferred Symbology Default
Scan the barcode below to set all Preferred Symbology entries to their default values.
Содержание 30-005
Страница 1: ......
Страница 24: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 24 24 Rev A...
Страница 25: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 25 Rev A...
Страница 26: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 26 26 Rev A...
Страница 27: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 27 Rev A...
Страница 28: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 28 28 Rev A...
Страница 60: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 60 60 Rev A...
Страница 165: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 165 Rev A Input Output Pin Out...
Страница 175: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 175 Rev A...
Страница 176: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 176 176 Rev A...
Страница 177: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 177 Rev A...
Страница 178: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 178 178 Rev A...
Страница 179: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 179 Rev A...
Страница 180: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 180 180 Rev A...
Страница 181: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 181 Rev A...
Страница 182: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 182 182 Rev A Integration...
Страница 183: ...Colibri serie 6 User s guide 2000 2012 C2R Technologie Sarl All rights reserved 183 Rev A...