![C-TEC QT601-2 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/c-tec/qt601-2/qt601-2_installation-and-programming-manual_3100300009.webp)
QT601-2 Quantec Controller
Installation & Programming Manual • Approved Document No. DNU6012001 Rev 5 • Page 9 of 42
QT615 Display
Interface
QT302RXS Slave IR Ceiling Receivers
(max. 3 per master IR receiver)
QT608C Corridor
Display
QT302RX Master
IR Receiver
QT688/2
Hi-Output
Sounder*
QT608CD1
Large Corridor Display
QT606A
Addressable
Overdoor Light
QT608C Corridor
Display
QT422RX
Radio Receiver
QT421
Integrity
Transmitter
Addressable Call
Point (with IR)*
QT608CD
Corridor Display
(without controls)
SPE0613 Stainless Steel
Isolatable Call Point*
SPE0614 Stainless Steel
Corridor Display
QT606 Slave
Overdoor
Light
Addressable
Call Point*
QT302RXS Slave IR
Receiver (max. 3 per
master call point)
Slave Panic
Button
QT607 Slave
Ceiling Pull
(max. 3 per
master call point)
QT602D Slave
Call Point
QT607
Slave Ceiling
Pull (max. 3 per
master
call point)
Call Point*
SPE0616
Stainless Steel
Call Point
Addressable
Call Point*
QT604 Monitoring
Point
4
4
2
3
QT302RXS
Slave IR Receiver
(max. 3 per
master
call point)
QT606 Slave
Overdoor Light
3
QT688/2
Hi-Output
Sounder*
3
3
2
2
3
If slave overdoor lights are fitted in corridors,
good practice is to loop the network in and out
of the overdoor lights and then spur off into the
relevant addressable call point inside the room.
QT606
Slave Overdoor
Light
4
QT606 Slave
Overdoor Light
To magnetic contacts on
a fire exit or drug cup-
board, or the n/o or n/c
switch on a door bell,
telephone, PIR, etc.
IR/RF
Transmitter*
IR/RF
Pendant*
QT612 Relay
Output Device*
To third party strobe, CCTV
trigger, auto-dialler or BMS
2
2
2
2
2
2
2
2
Addressable
Call Point*
IR/RF
Transmitter*
IR/RF
Pendant*
LIMB WIRING
•
Wire Limbs in a minimum of 4 core cable (7/0.2 mm
2
strand) twisted into one pair to reduce voltage drop.
• No. of Limbs per Splitter = 6; Max. length per limb = 60 metres.
•
Max. number of addressable devices per limb = 15; Max. number of addressable devices per Splitter = 60.
•
If possible, distribute devices at approximately equal distances along the length of the limb.
• Addressable devices require 2 network connections, Slave devices require 2, 3 or 4 cores as shown.
The above are general rules of thumb, if required refer to Pages 10 & 11 for more specific wiring details.
4
QT606 Slave
Overdoor Light
4
QT611 Universal
Programming
Device*
To third party
switch assembly
or Day/Night