![C-TEC QT601-2 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/c-tec/qt601-2/qt601-2_installation-and-programming-manual_3100300026.webp)
QT601-2 Quantec Controller
Installation & Programming Manual • Approved Document No. DNU6012001 Rev 5 • Page 26 of 42
Appendix 1 - Miscellaneous
Index of Location Descriptions
40 pre-set names are provided as standard and are listed
below. (An additional 45 custom names of 11 characters each
can be programmed at Access Level 3.)
Annexe Exit Quiet Room
Area FireExit Reception
Bathroom Flat Room
Bedroom Floor Shower
Conservtry Gents WC Sluice
Corridor Hairdresser Special
Dining Room Kitchen Staff Room
Disable WC Ladies WC Toilet
Display Laundry Treat Room
Door Lift TV Room
DoorBell Lounge Ward
Drugs Cab. Meeting Rm Zone
Entrance OD Light
ESMIUnit Phone
Set Ranges
Device Set Range: 2-255
Area Set Range: A-Z (26 Areas of call points, default = Area A)
Group Set Range: 1-32 (32 Groups of Displays, Group 1 default
to Area A; Group 2 default to Area B, etc.)
Zone Set Range: 1-64 (64 Zones of addressable overdoor lights
/ sounders, no defaults)
Equations
Group Routing Table = 3 (primary, night and divert)
Zonal Routing Table = 2 (Areas and devices)
Max. No. of terms in each equation 8 (eight)
Time Outs
Time before divert: Adjustable in steps 1, 2, 3, 4, 5, 6, 7, 8
minutes (default 1 minute)
Accept Time Out Period: Adjustable in steps 1, 2, 3, 4, 5, 6, 7,
8 minutes (default 1 minute)
Communication to the Output Device
Type: Serial - RS232
Data Rate: 9600 Baud
Protocol: 8 Data Bits, 1 Stop Bit, No Parity
Display Parameters
Note
: When there are concurrent Normal calls from Call Points
and Monitor Points the Monitor Point Call Rate is used.
Call Point Parameters
Addressable Overdoor Light Parameters
The periods above are subject to a tolerance of 10%.
Firmware Versions Required for New Features
The enhancements / programming functions listed on Page 4
are available from the 1 July 2010 and require the following
installed firmware versions:
• Quantec Controller version 10A5
• Display version 3.2
• Display Interface version 3.5
• Call Point version 1A06
• Radio Receiver version 4.0
• Surveyor version V1M03
• PCTOOLS version 4.2.
State
Display Beeper Rate (Sec)
Volume Backlight
NORMAL
Off
n/a
Off
UNASSIGNED/FAULT
0.5 On, 7.5 Off
Soft
Steady
PRESENCE
Off
n/a
Steady
STANDARD Call
0.5 On, 7.5 Off
Soft
Steady
HELP REQUIRED Call
2.0 On, 2.0 Off
Soft
Steady
EMERGENCY Call
0.5 On, 0.5 Off
Loud
As beep
ATTACK Call
0.1 On, 0.1 Off
Loud
As beep
MONITOR POINT
0.5 On, 0.5 Off, 0.5 On, 6.5 Off Soft
Steady
State
Rate
Lamp State
NORMAL
Off
-
UNASSIGNED
0.5 On, 0.5 Off
Red / Green alternating
PRESENCE
2.0 On, 2.0 Off
Green
CALL
2.0 On, 2.0 Off
Red
ASSIST
0.5 On, 0.5 Off
Red
EMERGENCY
0.5 On, 0.5 Off
Red / Green alternating
ATTACK
0.1 On, 0.1 Off
Red / Green alternating
State
Beeper Rate/Volume
Lamp State
NORMAL
As Display
As Call Point
UNASSIGNED
As Display
As Call Point
PRESENCE
As Display
As Call Point
CALL
As Display
As Call Point
ASSIST
As Display
As Call Point
EMERGENCY
As Display
As Call Point
ATTACK
As Display
As Call Point
APPENDICES