Start time: 9h30 ;
•
Stop time: 8h00.
The spa will enter stand-by mode every Monday at 9h30 and will remain in stand-by mode until 8h00 on
Tuesday morning.
The touch pad beeps twice when the stop time minutes are validated, and the screen stops blinking. Press
the UP arrow key to program the second stand-by cycle in the same way.
Nota bene 3 :
the maximum duration of a stand-by cycle is 23 hours and 59 minutes. To obtain this duration, set the
end time to 1 minute before the start time (in this case the stop time is programmed for the day after the
start time).
Nota bene 4 :
when the system restarts after a stand-by cycle, it automatically starts each of the auxiliary pumps for 10
seconds one after another, and then the blower. This prevents water from stagnating in the pipes for long
periods of time. While this is going on, the message "depriming, please wait" is displayed.
Nota bene 5 :
At the end of a stand-by cycle, if the set point temperature is significantly higher than the ambient
temperature, the spa will need to run for a long time before the set point temperature is reached again.
The longer the stand-by period, the more pronounced this effect will be, especially if the spa is not covered
with an isothermal cover.
We recommend that you cover your spa while its not in use, and that you program the spa to start at least
1/2 hour before you wish to use it.
42/48
2020/10 - Indice de révision : D - Code : 38050
SPAS
SPAS