38
GasAlertQuattro
Alarms
Table 7. Alarms
Alarm
Screen
Alarm
Screen
Multi-Gas Alarm
• Alternating low and high alarm siren
and flash
• Black box around gas flashes
• Type of alarm alternates
• Vibrator alarm activates
Over Limit (OL) Alarm
• Fast siren (downward tone)
• Fast flash
• Black box around gas flashes
• Vibrator alarm activates
Note: LCD may also display an under-
limit reading (-OL)
Low Battery Alarm
• Sequence of 10 rapid sirens and alternat-
ing flashes with 7 seconds of silence in
between (continues for 15 minutes)
• Battery icon flashes and the vibrator acti-
vates
• After 15 minutes, of the low battery alarm
sequence, the detector enters critical bat-
tery alarm. Refer to Critical Battery
Alarm.
Critical Battery Alarm
• Fifteen minutes after the low battery alarm
activates, a sequence of 10 rapid sirens and
alternating flashes with 1 second of silence
in between (sequence reactivates seven
times)
• Vibrator alarm pulses
•
Low Battery Powering Off
displays and the
detector deactivates