16
Field Scan 2x with Live Trigger Feature
Field Scan is a revolutionary new feature for the Bushnell Trophy Cam HD
Aggressor, which allows you to monitor your food plots or field edges with time lapse
images or video. When set to “On”, the Trophy Cam HD Aggressor will take a photo
(or record a video clip) automatically at your choice of intervals (for example, once
every five minutes) during one or two blocks of time you set up for each day, without
requiring a trigger from an active animal. This has the advantage of giving you
the ability to monitor the edge of a field that might be 50 or 150 yards away from the
camera out of the PIR sensor’s range. The result is an effective range much greater
than it would normally be, with the camera dependant on triggers generated by nearby
animals. This is a great tool for hunters to scout an entire field with only one camera.
If an animal does enter the area covered by the PIR sensor and generate a trigger
event during a time in between the Field Scan intervals you set, the camera will capture
an image or video just as it normally would, based on your other menu settings. Here’s
how to setup and use Field Scan (be sure you’ve set the current time in “Set Clock”
first, so your Field Scan recording will stop and start at the correct times of day):
1. Move the main switch to SETUP, then press MENU.
2. Keep pressing the RIGHT key, stepping through the Setup Menu until you reach
Field Scan.
3. Press the UP key to select On, and press OK
(Step 1,
pg.18
)
. You will see "A",
representing the first block of time you can define (a second block of time later
in the day, "B" can also be setup if you wish). Press OK
(Step 2)
. This takes
you to the screen to set Start and Stop times, which determines the clock times
when the first block of Field Scan recording will begin and end for each day.
You can set these times to the exact hour and minute you want, for a recording
“window” that lasts anywhere from just a minute to a full 24 hours.
4. Set the [Start] and [Stop] times, beginning with the Start hour, using the UP/
DOWN keys to change the setting
(Step 3)
. The hour setting is based on a 24-
hour clock, with “00” hours = midnight, “12” hours = noon, “23” hrs = 11PM,
etc. To move to the next setting, press the RIGHT key, change the minute for
the Start time with UP/DOWN, then on to the hour and minute settings for the
Stop time.
5. After you finish setting the Stop minutes, press OK to confirm your settings for
the first block of Field Scan recording. If desired, you can create a second block
Содержание 119773C Aggressor
Страница 1: ...Model s 119774C 119775C 119776C 119777C I N S T R U C T I O N M A N U A L 01 15...
Страница 2: ......
Страница 3: ...3...
Страница 14: ...14 Fig 4 Selecting Parameter Settings 4a 4b Press MENU Press DOWN Press OK...
Страница 39: ......